Owner / Applicant Information
Stein Jay
4411 Coldwater Road LLC
10689 N PENNSYLVANIA STREET
SUITE 100
INDIANAPOLIS IN 46280
Phone 4803851301
Email [email protected]
Submitter Information
Donald Alexander
 
25001 Emery Road, Suite 400
 
Cleveland IN  
Phone 2162233258
Email [email protected]
Designer Information
Donald Alexander
Donald W. Alexander
25001 Emery Road, Suite 400
 
Cleveland OH  
Phone 2162233252
Email [email protected]
Project Information
Fort Wayne IN - Dick's Sporting Goods T.I.
309 Coliseum Blvd
 
FORT WAYNE OH 46805
County ALLEN
Project Type New   Addition Y Alteration Y Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? yes No
Violation Issued by: NA
Local Building Official
Phone: 2604497224 Email: [email protected]
Local Fire Official 
2604497224 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC 1004 Occupant load
Conditions: 2014 Indiana Building Code (IBC 2012), 
Section 1004 Occupant Load, Table 1004.1.2 
Maximum Floor Area Allowances: per occupant M-use Mercantile Occupant load factor is  30sf/occ. for grade floor and basement areas and 60sf/occ for areas on all other floors.

We are requesting to use the M-use Mercantile Occupant load factor of 60sf/occ as shown  on the Tenant Improvement Set.
 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: We have already designed the both the Shell and Tenant Improvement Sets for a total  occupant load of 1,384 occupants. This is more than will ever be inside the store at one time.  To revert to the 30sf/occ load factor would presume that we would have an additional 1,000  occupants. This would require more restroom fixtures, a redesign of all 5 main egress doors  to be almost twice as wide, and a reduction in storage capacity. Resulting in additional costs  of altered construction elements.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The 2015 International Building Code and all subsequent versions have corrected this to be  60sf/occ on all floors. The majority of all other states use the 2015 IBC or newer version of this building code. This reduction of occupancy would not be averse to public health, safety, or  welfare. The new versions of the IBC code would not consistently use the M-use Mercantile  Occupant load factor of 60sf/occ if it caused any harm to the public.