Project Information
McKenzie Center for Innovation & Technology
7250 East 75th Street
Indianapolis IN 46256
County MARION
Project Type New   Addition Y Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3173275544 Email: [email protected]
Local Fire Official 
3173275544 Email: [email protected]
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
507.4, 2014 IBC
Conditions: The expanded building will not have 60 feet of separation for 11% of the building perimeter.   11% of the perimeter will have 42 feet of frontage along the east side of the site.  Code  requires 60 feet of space surrounding a building designed as unlimited area.

The project scope involves additions on 2 stories totaling 190,000 sq ft, and renovation of  remaining existing area of 105,800 sq ft.  Project scope also includes demolition of 50,200 sq  ft of existing area.  The project will create the McKenzie Center for Innovation & Technology,  which will significantly expand career training opportunities.  The building currently serves  as the McKenzie Career Center.  The original building was constructed in 1995, with  additions in 1997, 2003, and 2016.  The building is classified as Type IIB Construction and will be protected throughout with an automatic sprinkler system.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.   The building (existing and new) will be protected throughout with a sprinkler system per  NFPA 13. 

2.    Existing fire access roads will be maintained around the perimeter of the building,  including along the east side.

3. NFPA 80A, Protection of Buildings from Exterior Fire Exposures, states in Sec. 5.6.3 that  where exposing buildings are protected throughout with an automatic sprinkler system, no  exposure hazard is considered to exist.
 
4. Based upon automatic sprinkler protection in the building, the minimum 42 feet of frontage,  and fractional perimeter of the building lacking 60 feet of frontage, the proposed expansion of  the building will not be adverse to safety.

5. Similar variances have been approved for lack of 60 feet of separation for school buildings,  including 26-06-71, 25-02-23a, 20-02-06, 20-03-14, 16-01-19, 18-05-30, 18-02-21, 16-07-55,  16-07-59, and 16-07-60.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Hardship is the restricted site from east to west.  The proposed construction cannot be  placed on the site to meet the 60 feet of frontage based upon configuration of the site and  maintaining existing building configuration.
Variance Details
Code Name:  Other Code (Not in the list provided)
1016.2, 2014 IBC

1016.2, 2014 IBC
Conditions: Maximum egress travel distance from the new 2nd floor addition will be 295 feet, exceeding  code limit of 250 feet.  See plan exhibit for location of areas exceeding 250 feet travel  distance.

The project scope involves additions on 2 stories totaling 190,000 sq ft, and renovation of  remaining existing area of 105,800 sq ft.  Project scope also includes demolition of 50,200 sq  ft of existing area.  The project will create the McKenzie Center for Innovation & Technology,  which will significantly expand career training opportunities.  The building currently serves  as the McKenzie Career Center.  The original building was constructed in 1995, with  additions in 1997, 2003, and 2016.  The building is classified as Type IIB Construction and will be protected throughout with an automatic sprinkler system.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  Five (5) egress stairs will be provided from the 2nd floor, leading to multiple exterior exits in  all directions on the 1st floor.

2. The existing building is protected throughout with an automatic sprinkler system.  The  addition will also be sprinkler-protected.

3. The Indiana Building Code prior to adoption of the International Building Code in 2003  permitted egress travel distance of up to 325 feet in a sprinklered E Occupancy. 
 
4.    Similar variances have been granted for schools to permit travel distance of up to 325 feet and beyond since 2003, including 07-07-29a, 07-09-10, 08-03-13, 09-09-20, 12-09-18, 13-10- 22, 14-01-64, 14-02-32, 16-07-51, 17-03-71, 18-02-28c, 18-07-43, 19-01-33, 20-04-32a, 20- 06-85a, 21-03-33a, 21-10-52, 22-02-24b, 22-05-75, 23-03-55b, 23-05-61, 23-07-48a, 23-06- 15, 24-06-18, 24-08-63, 25-01-81, 25-07-04, 26-01-05, 26-06-33, and 26-06-71.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Due to site restrictions and functional needs, the addition is situated as proposed.  Based  upon the proposed configuration of the addition along the south end of the existing building, it  is not feasible to meet the 250-ft limit for the portion of the 2nd story as indicated.