Project Information
WTEC Crossdock Warehouse Expansion 
1851 Technology Drive
Washington IN  
County DAVIESS
Project Type New   Addition Y Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order?    
Violation Issued by: NA
Local Building Official
Phone: 3172724438 Email: [email protected]
Local Fire Official 
3172724438 Email: [email protected]
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC, 507.4
Conditions: The code permits the area of a Group B, E, F, M or S building no more than two stories  above grade plane of any construction type, to be unlimited where the building is provided  with an automatic sprinkler system throughout in accordance with NFPA 13 and is  surrounded and adjoined by public ways or yards not less than 60 feet in width. The request is for the existing building and addition to be unlimited in area with less than 60 feet in width  on all sides. The South side of the existing building is 15-16 feet from the property line.  

The project involves an addition approximately 81,000 square feet to the existing building. The existing facility is approximately 59,000 square feet and 2-stories. The building is classified  as a B, F-1, S-1 Occupancy. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. There is a railroad right of way to the South of the property line that is nearly 80 feet wide.  The addition has over 60 feet of frontage on all sides. 

2. The existing building is fully sprinklered and the addition will be fully sprinklered in  accordance with NFPA 13.

3. NFPA 80 A, Recommended Practice for the Protection of Buildings from Exterior Fire  Exposure section 5.6.3 state no exposure hazard exists between buildings which are  properly sprinklered for the hazard involved. 

4. Based upon lack of any fire exposure to other properties or buildings, automatic 
sprinkler protection, and the nearly 80 foot railroad right of way, the lack of 60 feet to a property line on the south side of the existing building will not be adverse to safety. Similar variances  have been approved for lack of 60 feet of separation under a variety of circumstances,  including 25-02-34, 24-07-07, 23-12-84, 23-05-03, 22-01-28, 23-05-24, 20-02-06, 19-10-23,  16-09-35a, 16-01-19, 18-05-30, 18-10-32, 18-05-52c, 18-07-42a, 18-02-21, 16-07-55, 16-07- 59, 15-11-36, and 16-07-60.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The owner's undue hardship involves trying to maximize the site to meet the building's area  and programming needs. Building a 254 foot long 4 hour wall at the existing exterior wall to  technically allow the required 60 foot of frontage is not reasonable given there is a railroad  right of way nearly 80 feet wide on that side of the building.