Owner / Applicant Information
Philip Kenney
F A Wilhelm Construction Co INC
3914 PROSPECT STREET
INDIANAPOLIS IN 46203
Phone 3173595411
Email [email protected]
Project Information
Elanco
430 S White River PKWY WDR
Indianapolis    
County MARION
Project Type New   Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No yes
Violation Issued by: LBD
Local Building Official
Phone: 3175185525 Email: [email protected]
Local Fire Official 
Phone: 3175185525 Email: [email protected]
Variance Details
Code Name: 2014 Indiana Mechanical Code (675 IAC 18-1.6)
507.9 Clearances for type 1 ho
Conditions: A type 1 hood Shall be installed with a clearance to combustibles of not less than 18 inches
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w

1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: A hard pan ceiling constructed of fire rated drywall 11 inches away from the hood. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The question to how this would burden the owner to resolve these 2 violations. Is loss of  revenue to the tenant in their cafeteria, for a day to allow a crew to hang stainless panels to  the ceiling of the affected area. The second burden would be the cost of construction labor  and materials including the relocation of a sprinkler head in front of the area in question.

Variance Details
Code Name: 2014 Indiana Mechanical Code (675 IAC 18-1.6)
506.3.1.2 Makeup air ducts
Conditions: Duct insulation installed within 18 inches of a type 1 hood shall be non combustible or shall  be listed for the application
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The duct work is Attached to a metal box that is non combustible. That holds the flex duct  away
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The question to how this would burden the owner to resolve these 2 violations. Is loss of  revenue to the tenant in their cafeteria, for a day to allow a crew to hang stainless panels to  the ceiling of the affected area. The second burden would be the cost of construction labor  and materials including the relocation of a sprinkler head in front of the area in question.