Owner / Applicant Information
Brad DeRome
Muncie Community Schools
4301 SOUTH COWAN ROAD 
MUNCIE IN 47302
Phone 7657475211
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Designer Information
Sarah Hempstead
Schmidt Associates
415 Massachusetts Avenue
Indianapolis IN  
Phone 3172636226
Email [email protected]
Project Information
Muncie Area Career Center Relocation
4301 South Cowan Road
Muncie IN 47302
County DELAWARE
Project Type New   Addition   Alteration Y Existing   Change of Occupancy Y
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 7657474862 Email: [email protected]
Local Fire Official 
7657474862 Email: [email protected]
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
503.1, 2014 IBC
Conditions: The existing building to be converted to E Occupancy from B Occupancy will exceed the  area allowed for Type IIB Construction.  Allowable area is 22,937 sq ft for the area to be  changed to E Occupancy when considered a separate building - actual is 30,746 sq ft.  

The existing building, an Ivy Tech facility, is a 1-story structure built in 1967, with subsequent  additions in 1973, 1977, and 1978.  Total building area is 60,831 sq ft.  The project will convert  Units A and B (30,746 sq ft) for use as the Muncie Area Career Center, which is the existing  vocational training program for high schooljuniors and seniors from participating high  schools in Blackford, Delaware, and Randolph counties.  The program is currently located in a 1950's era facility on the north side of Muncie.  See attached narrative for additional  information about the program.  
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.    Existing wood stairs, mezzanines and interior partitions will be demolished as part of this  project.
2.    A fire alarm system is existing throughout the building.  Smoke detection is provided in  corridors in the project area - not required by code.  Exterior exits are provided to the exterior from major lab spaces along the south side of the building.
3. An existing 1-hour fire barrier separating Units A and B from the rest of the building will be  upgraded to a 2-hour fire barrier. 
4.    The existing egress corridor is of 1-hour construction in compliance with requirements  for the original construction of this area in 1977-1978.  Egress lighting and exit signs will be  provided per code.  Egress travel distance will be a maximum of 175 feet, less than the  maximum 200 feet per code.
5. Mechanical systems in the building are approximately 5 years old.  Accessible rest room  facilities are provided.
6. Based upon the features provided, lack of compliance with current code allowable area will not be adverse to safety.  Codes in effect in 1975-1986 permitted unlimited area for 1-story E  Occupancy buildings without provision of an automatic sprinkler system.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule would require additional upgrades to the building that are  disproportionately expensive relative to the cost of construction.  Cost of construction is  approximately $225,000.  The cost for sprinkler protection throughout alone is estimated at  $350,000 - which is the only method available to comply with allowable area limits.  The  proposed location for the Career Center program will be more safe than the current location in the 1950's era building.  The proposed location will provide much better facilities for the  program.  
Variance Details

Variance Details
Code Name:  Other Code (Not in the list provided)
903.2.3, 2014 IBC
Conditions: The portion of the existing building to be converted to E Occupancy from B Occupancy will  not be provided with an automatic sprinkler system.  

The existing building, an Ivy Tech facility, is a 1-story structure built in 1967, with subsequent  additions in 1973, 1977, and 1978.  Total building area is 60,831 sq ft.  The project will convert  Units A and B (30,746 sq ft) for use as the Muncie Area Career Center, which is the existing  vocational training program for high school juniors and seniors from participating high  schools in Blackford, Delaware, and Randolph counties.  The program is currently located in a 1950's era facility on the north side of Muncie.  See attached narrative for additional  information about the program.  
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.    The building is Type IIB Construction - noncombustible construction.  Existing wood  stairs, mezzanines and interior partitions will be demolished as part of this project.
2.    A fire alarm system is existing throughout the building.  Smoke detection is provided in  corridors in the project area - not required by code.  Exterior exits are provided to the exterior from major lab spaces along the south side of the building.
3. An existing 1-hour fire barrier separating Units A and B from the rest of the building will be  upgraded to a 2-hour fire barrier. 
4.    The existing egress corridor is of 1-hour construction in compliance with requirements  for the original construction of this area in 1977-1978.  Egress lighting and exit signs will be  provided per code.  Egress travel distance will be a maximum of 175 feet, less than the  maximum 200 feet per code.
5. Mechanical systems in the building are approximately 5 years old.  Accessible rest room  facilities are provided.
6. Based upon the features provided, lack of sprinkler protection will not be adverse to safety.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Imposition of the rule would require additional upgrades to the building that are  disproportionately expensive relative to the cost of construction.  Cost of construction is  approximately $225,000.  The cost for sprinkler protection throughout alone is estimated at  $350,000.  The proposed location for the Career Center program will be more safe than the  current location in the 1950's era building.  The proposed location will provide much better  facilities for the program.