Owner / Applicant Information
Mike Malaski
Crown Point Community School Corporation
200 EAST NORTH STREET
CROWN POINT IN 46307
Phone 2196633371
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Designer Information
Joseph Briggs
Gibraltar Design,Inc
9102 North Meridian Street
Indianapolis IN  
Phone 3175805777
Email [email protected]
Project Information
Winfield Elementary School
13128 Montgomery Street
Crown Point IN 46307
County LAKE
Project Type New   Addition Y Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 2196622665 Email: [email protected]
Local Fire Official 
2196622665 Email: [email protected]
Phone:

Variance Details
Code Name: 12-4-12 Existing Buildings; Additions or Alterations
Rule 4, Section 12(f), GAR
Conditions: The proposed expansion of four (4) existing classrooms (1,438 sq ft additional area) will not  be provided with a fire-rated separation from the existing 1-story Area 1A in the building,  which has 27,413 sq ft of area.  A 2-hour fire wall is required because of exceeding  allowable building area (18,125 sq ft) for Type IIB Construction per current code and  allowable nonsprinklered fire area per current code.  Current code limits nonsprinklered fire  area to 12,000 sq ft.  Additional unseparated sq footage will be two (2) open exterior canopies (760 sq ft total).

The existing building and the addition are both classified as E Occupancy and Type IIB  Construction.   
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The fire area of Area 1A will be reduced as a result of this project, due to demolition of an  existing gym and administrative area, to be replaced with a new gym and administration area  separated by a new 2-hour fire wall.  Existing fire area of Area 1A is 29,062 sq ft - proposed  will be 28,851 sq ft.  
2. The affected classrooms will be provided with smoke detection, connected to the building  fire alarm system.
3. The addition does not increase egress travel distance from existing areas, and does not  otherwise adversely impact the existing building.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The addition cannot be feasibly separated from existing area since an expansion of existing  rooms. 

Variance Details
Code Name: 2012 Indiana Plumbing Cod, (675 IAC 16-1.4)
405.3.2
Conditions: Lavatories associated with rest rooms for 3 kindergarten classrooms and a special ed/flex  classroom will be located outside the rest rooms.  The IPC requires lavatories in employee  and public toilet rooms to be located within the room.  
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The proposed location of the lavatories comply with the old schoolhouse planning rules
requirements for hand washing facilities in public schools in 410 IAC 6-5.1-5(s)(4), which  states:
Restrooms shall be equipped with lavatories or other satisfactory hand washing facilities, or  such equipment shall be installed in an adjacent room through which the users must pass  upon egress from the restroom. The proposed design is typical for elementary school design over the past 30+ years. 

2. Similar variances have been granted previously, including 18-05-15, 18-05-14, 18-03-34,  19-10-52, 19-07-28, and 19-05-05.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Location outside the toilet room provides staff with enhanced supervision to ensure proper  hand washing of younger and special ed students after use of rest rooms.