Owner / Applicant Information
Dr.Brad Yates
Bluffton Harrison Metropolitan School District
805 EAST HARRISON STREET
BLUFFTON IN 46714
Phone 2608242620
Email [email protected]
Submitter Information
Melissa  Tupper
RTM Consultants, Inc.
6640 Parkdale Place
Indianapolis IN  
Phone 3173297700
Email [email protected]
Designer Information
Jack E Daniel
MartinRiley Architects Engineers
221 West Baker Street
Fort Wayne IN  
Phone 2604227994
Email [email protected]
Project Information
Bluffton Harrison Elementary School Add Renov
1100 East Spring Street
Bluffton IN 46714
County WELLS
Project Type New   Addition Y Alteration Y Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order?   yes
Violation Issued by: SFM
Local Building Official
Phone: 2608246068 Email: [email protected]
Local Fire Official 
2608246068 Email: [email protected]
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC, 1004.1.2, 1015.1
Conditions: The calculated occupant load of 4 kindergarten rooms (1039, 1042, 1044, and 1048) exceed  49 requiring 2 means of egress. The variance request is to permit a single means of egress  from each of the rooms. 
   
The project involved 3 additions totaling 39,054 square feet and a renovation of the existing  school. The school is Type IIB construction, unlimited in area, and protected throughout with  an automatic sprinkler system. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The maximum student roster for a kindergarten classroom would be 25. Typically there are  18-22 students in a classroom for kindergarten. In addition would be one teacher and one  instructional aide. 
 
2. The building is protected throughout with an automatic sprinkler system in accordance with  NFPA 13.

3. The building has a fire alarm system throughout. 

4. The maximum common path of travel from the rooms is 61 feet, within the permitted 75 feet  for an E Occupancy with a single means of egress.

5. The room will be posted for a maximum occupant load of 49.  Sec. 1004.1.2, exception, 2012 International Building Code (exception deleted by Indiana amendment), permits the design  occupant load to be reduced ¿where approved by the building official¿.

6. Similar variances have been granted in the past to limit the occupant load of rooms and  buildings. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule would require two exits per room as well as side walks to the public way for rooms that will not have an occupant load that exceeds 49.