Project Information
University of Notre Dame New Women's Residence Hall
Holy Cross Drive and Wilson Drive
Notre Dame MO 46556
County ST JOSEPH
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5742359554 Email: [email protected]
Local Fire Official 
5742359554 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
717.5.4.1 2014 IBC
Conditions: Smoke dampers will not be installed in ventilation supply ducts serving corridors since  variance was granted for dorm room doors to not be required to have door closers (variance #18-06-50).
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The building will be protected throughout with a sprinkler system per NFPA 13.  

2. The corridors will be provided with a smoke detection system connected to the building fire  alarm system - corridor smoke detectors are not required by code.  Each sleeping room will  be provided with single-station smoke alarms, as required.

3. This request is identical to approved installations for three (3) recently constructed  residence halls at UND.  
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: The hardship is the initial installation cost and ongoing cost of maintaining smoke dampers  that would provide no real life safety benefit, since a variance was granted for dorm room  doors to not be required to have door closers (variance #18-06-50). In other words, due to  the fact that there is no real smoke barrier at the door to each bedroom, adding smoke  dampers in the duct serving the corridor would not create an effective smoke barrier.