Owner / Applicant Information
Monica J Berning
Blackhawk Commons Limited Partnership
500 S. FRONT ST, 10TH FLOOR
COLUMBUS OH 43215
Phone 2024898537
Email [email protected]
Designer Information
Monica Jo   Berning
PCI Design Group, Inc.
500 S. Front St, Ste 975
Columbus OH  
Phone 6143960014
Email [email protected]
Project Information
Blackhawk Commons Apartments
509 East 4th St
SHERIDAN   46069
County HAMILTON
Project Type New   Addition   Alteration Y Existing Y Change of Occupancy Y
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3177585293 Email: [email protected]
Local Fire Official 
Phone: 3177585293 Email: [email protected]

Variance Details
Code Name:  Other Code (Not in the list provided)
Table 503 of IBC 2014
Conditions: The actual area for the R2 portion of the building based on a separated use exceeds the  allowable area for the first floor by 6%. See calculations on attached plans.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The assembly (A4) occupancy will be provided with a complete NFPA 13 system. The A4  occupancy is 38% of the allowable area. Floors other than the first floor for the R2 occupancy  are less than the allowable area by 26% on the 2nd floor and 38% on the 3rd floor. Overall the  entire R2 occupancy when combining all floors is 54,482 SF and the overall allowable area is  112,000 SF. The R2 occupancy will be sprinklered with a NFPA 13R system.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: The cost to install a NFPA 13 system is twice the amount to install 
a NFPA 13R system.