Owner / Applicant Information
Walter Todd
Southwest Allen County Schools
4824 HOMESTEAD ROAD
FORT WAYNE IN 46814
Phone 2604312080
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Project Information
Summit Middle School Locker Installation
4509 Homestead Road
Fort Wayne IN 46804
County ALLEN
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 2604997131 Email: [email protected]
Local Fire Official 
Phone: 2604997131 Email: [email protected]

Variance Details
Code Name: 12-4-12 Existing Buildings; Additions or Alterations
Rule 4, Section 12(d)
Conditions: Lockers will be added within corridors to accommodate an expected increase in enrollment.  State Code Enforcement has requested that a variance be filed to validate corridor width  requirement based upon egress capacity.  Corridors affected are 10 feet existing in width.   Rows of lockers to be placed alongside corridors in several locations will be 12 inches in  depth, reducing corridors to 9 feet in width.  Per the attached variance exhibit, the required  width of corridors will be maintained based upon required egress capacity.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.   Based upon an analysis of the calculated occupant load, corridor configuration, and  arrangement of exits, the minimum width of 6 feet for E Occupancy corridors will continue to  control the required corridor width in the building.  
2.    Corridors are without dead ends, and therefore in all cases permit travel in two (2)  directions to multiple exits.  As illustrated, the corridor width is required to be at least ½ of that  required for the occupant load served.  
3. A total of six (6) exterior exits serve the classroom wing affected by the locker installation.
4. The building is protected throughout with an automatic sprinkler system.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: The lockers are needed to accommodate an expected surge in enrollment in the coming year based upon Allen County school redistricting, as well as continued growth in the area in  upcoming years.