Owner / Applicant Information
Chris Teeter
DT Retail Properties, LLC
500 VOLVO PARKWAY
CHESAPEAKE VA 23320
Phone 7573215000
Email [email protected]
Submitter Information
Linda Snapp
Clark Geer Latham & Associates
3901 Springhill Ave
Mobile IN  
Phone 2513447073
Email [email protected]
Designer Information
Linda G. Levin Snapp
Clark Geer Latham and Associates, INC
3901 Springhill Ave
Mobile AL  
Phone 2513447073
Email [email protected]
Project Information
Dollar Tree  Goshen IN
2323 Lincolnway E
GOSHEN AL 46526
County ELKHART
Project Type New   Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5745341811 Email: [email protected]
Local Fire Official 
5745341811 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
903.2.11.1.2 
Conditions: Building is not required to be nor is sprinkled.
The building is 81'-4" deep and therefore is required to have openings in 2 sides in each 50  linear feet
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The building is equipped with a fire alarm system
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The plans were approved without this opening. The building construction is complete and in  order to add this opening there would be structural modifications required which would cause a hardship. This is a PEMB with structural girts 24" o.c. that run horizontal.
The sheetrock would have to be removed and the girts cut and modified.