Owner / Applicant Information
Bryan D Duncan, PE
Indiana State University
951 SYCAMORE STREET
TERRE HAUTE IN 47809
Phone 8122378195
Email [email protected]
Submitter Information
Edwin L Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Designer Information
William  A Browne, Jr, FAIA
Ratio Design
101 South Pennsylvania Street
Indianapolis IN  
Phone 3176334040
Email [email protected]
Project Information
Indiana State University Sycamore Dining Commons
400-410 Mulberry Street
Terre Haute IN 47809
County VIGO
Project Type New   Addition Y Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 8122444903 Email: [email protected]
Local Fire Official 
8122444903 Email: [email protected]
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
1008.1.4.4, 2014 IBC
Conditions: Rolling security grilles will be utilized to secure the dining facility from unlawful entry after  hours.  A portion of the required egress width for the dining area (when considered fully  occupied) will be obstructed by the grilles.  Total required egress width is 246 inches.  The  egress width provided when security grilles are closed after hours is 144 inches.   Code  permits security grilles as designed only for Groups B, F, M and S Occupancies.  The  space is classified as A-2 Occupancy.
The existing 1-story + basement dining and food services commons is part of the 1960's era  Sycamore Towers.  The commons is centered among the four (4) connected residence  towers.  Sycamore Towers is constructed of a combination of cast-in -place and precast  concrete.  The project scope is a complete renovation of the existing dining and food  services area, and two (2) separate additions totaling 10,826 square feet of additional floor  area. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.   The dining hall will be protected throughout with a sprinkler system per NFPA 13 as part of  this project. 
2. The grilles will only be closed after dining hours, and will be open when the dining area is  occupied by other than staff.
3. The grilles will be openable from the inside without the use of a key or special knowledge or effort.
4. Four (4) separate exits are available from the dining area at all times, unobstructed by the  grilles.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The security grilles are necessary to secure entry to the dining facility after hours.