Owner / Applicant Information
David D Lee
Simon Property Group
225 WEST WASHINGTON STREET
INDIANAPOLIS IN 46204
Phone 3172638157
Email [email protected]
Submitter Information
Ralph D Gerdes
Ralph Gerdes Consultants, LLC
5510 S. East St.
Indianapolis IN  
Phone 3177873750
Email [email protected]
Designer Information
Alan E Tucker
CSO Architects
8831 Keystone Crossing
Indianapolis IN  
Phone 3178487800
Email [email protected]
Project Information
Circle Center Mall
49 West Maryland Street
Indianapolis IN 46204
County MARION
Project Type New   Addition   Alteration   Existing Y Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3173278700 Email: [email protected]
Local Fire Official 
3173278700 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
2014 InFC 807.1
Conditions: Mall food court dining area will have an artwork piece hung from the ceiling. The art will  involve stainless steel, wire cables, and plastic sheet material.  Fire Code requires  combustible decorative materials to be tested per NFPA 701.
The plastic has not been tested per NFPA 701.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The product has been tested per ASTM D 635 and E 84.  The building code permits the  product to be used in roof panels, skylights, wall panels and storefront signage (building  construction).

The building is fully sprinklered per NFPA 13.

Flame spread index is approximately 140.  Self ignition temperature is 910 F.  Burn rate is  about 1.5 in per minute per ASTM D 635.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: NFPA 701 test is for fabrics, textiles and film material, thus does not seem appropriate for  plastic sheet.  The ASTM D 635 test is for plastic material and the code permits it in the  building construction.