Owner / Applicant Information
Jim McBee
North Montgomery School Corporation
480 W 500 NORTH
CRAWFORDSVILLE IN 47933
Phone 7653592112
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Designer Information
Sarah Hempstead
Schmidt Associates
415 Massachusetts Avenue
Indianapolis IN  
Phone 3172636226
Email [email protected]
Project Information
Northridge Middle School Renovation
482 West 500 N
Crawfordsville IN 47933
County MONTGOMERY
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 7653646493 Email: [email protected]
Local Fire Official 
7653646493 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
1018.6, 2014 IBC
Conditions: A reconfigured egress corridor will have one (1) of the two (2) required means of egress  through the existing gymnasium.  Code does not permit a fire-rated corridor to pass through  an intervening room unless classified as a 'foyer, lobby, or reception room'.
The project involves interior renovation of the existing building, including moving the  administration area and other measures to improve school safety and security.  
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The gymnasium will be provided with smoke detection tied to the building fire alarm system.

2.  The corridor in question will be secured to prevent access to the academic areas of the  building only after hours.

3.  Egress through the gymnasium will not be adverse to safety, as it is a large volume space  with visibility and ready access to two (2) exits from the gym.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The project involves reconfiguration of existing circulation paths in order to prevent after- hours access to academic areas of the building, as well as improve overall security by  moving the administration area to create a secure entrance.  Based upon the existing layout  of the building, the proposed egress scheme for the corridor in question is the best option  without compromising security needs.