Owner / Applicant Information
Richard & Lauren Rush
 
4150 BROADWAY ST
INDIANAPOLIS IN 46205
Phone 3174076303
Email [email protected]
Submitter Information
Mike Davidson
Meridian Pro Service
1143 East 56th Street
Indianapolis IN  
Phone 3176705131
Email [email protected]
Project Information
Attic Project - Stairway
4150 Broadway St 
Indianapolis IN 46205
County MARION
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3173274104 Email: [email protected]
Local Fire Official 
Phone: 3173274104 Email: [email protected]

Variance Details
Code Name:  Other Code (Not in the list provided)
2005 Residential Code R311.5.2
Conditions: A stair is being from the second floor to the third floor of the residence to provide a single  bedroom in the attic.  In order to maximize head clearances the landing of the stairs is  located as low from the top plate/bottom of the rafter while maintaining head clearances for  the floor below. The heads clearance from each tread will be no less than 6'-0" and the  landing will be from 4'-5" to 7'-0" due to the 8:12 slope of the roof.  Code requires the  minimum headroom in all parts of the stairway shall not be less than 6'-8" measured  vertically from the sloped plane adjoining the tread nosing or from the floor surface of the  landing or platform. This is class II (single family dwelling).
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. This is a 1914 structure
2. Indiana Residential Code calls for any new stairs to have head clearance of 80" minimum 
3. The existing head clearance are as low 6'-4" on certain areas of the first to second floor  stairs
4 The attic bedroom will be a single occupiable space and will provide a 48"x48" operable  window for emergency egress as required 
5 Lowering the landing further would cause additional conflicts with existing conditions such  as transom windows to the exterior, existing door frames and door swings.  To fully comply  would cause on the first-second floor landing head clearance
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Building a dormer above the stair is the most expedient way to build enough head clearance  to conform to code
a. As a 1914 home providing a dormer that would be visible from the street that does not match the character slope style of the home would inversely effect the authenticity of the home and  likely the property value of this home and potentially neighbors who have similar homes
b. Providing dormer at this location was not established as part of the original construction  budget from which owner secured financing  The cost to build the additional former would  result in undue hardship.
c.The owner cannot provide another point of access to the level that does not dramatically  reduce square footage with in current occupiable (non-storage) square footage or the would  require further disruptive construction (addition on exterior) that would cause structural and  financial hardship