Owner / Applicant Information
Michael Eaton
16 New Jersey LLC
3657 SOUTH SARE ROAD
BLOOMINGTON IN 47401
Phone 8123362421
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianaplis IN  
Phone 3173297700
Email [email protected]
Designer Information
Brian  Schubert
DKGR
10 WEST MARKET ST, SUITE 800
INDIANAPOLIS IN  
Phone 3176140053
Email [email protected]
Project Information
16 New Jersey
319 E 16th St
INDIANAPOLIS IN 46202
County MARION
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No yes
Violation Issued by: LBD
Local Building Official
Phone: 3173275544 Email: [email protected]
Local Fire Official 
3173275544 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
1022.7, 2014 IBC
Conditions: A nonrated exterior window will be located within 10 feet of unprotected exterior windows in  one (1) of the enclosed stairs on each of the 2nd, 3rd, and 4th floors.
    
The project involves construction of a 5-story + basement building consisting of lower level  and 1st floor parking, 1st floor commercial tenant space, three (3) floors of residential  dwelling units, and a 5th level tenant amenity Lounge and on that same level an occupied  roof terrace. The project will employ the horizontal building separation ¿podium¿ option per  Sec. 510.2, with the basement and 1st floor of Type IA Construction, and the top 4 floors  designed as Type VA Construction.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.   The Type VA building will be protected throughout with a sprinkler system per NFPA 13R.  
2.   A sprinkler will be located at the ceiling level within 12 inches of the windows exposing the  stairway to protect the stair from fire exposure.
3. This variance has been granted for several projects recently, including 18-06-50d, 16-12- 31d, 16-11-25b, 16-10-23c, 16-05-73k, and 15-07-53d.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The openings are needed to provide natural light and ventilation into the dwelling units.  Providing a fire-rated window assembly would not permit an operable window needed for  natural ventilation.

Variance Details
Code Name: 2009 Indiana Electrical Code (675 IAC 17-1.8)
110.26
Conditions: The electrical closet on the 4th floor will have a clearance of 35 inches in lieu of the required  36 inches in front of the electrical panel. 
   
The project involves construction of a 5-story + basement building consisting of lower level  and 1st floor parking, 1st floor commercial tenant space, three (3) floors of residential  dwelling units, and a 5th level tenant amenity Lounge and on that same level an occupied  roof terrace.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The 1-inch difference in clearance will allow the necessary access to the electrical panel  for service and maintenance.
2. Similar variances have been granted previously for relatively small discrepancies in  clearances, including most recently 18-04-26b.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The cost estimate to remedy the 1-inch discrepancy is $10,530.