Owner / Applicant Information
James Passios
Superior Property Holdings
18 Shipyard Drive 
Hingham ME 02043
Phone 5742571665
Email [email protected]
Submitter Information
Dennis Gadacz
Midstates Elevator Company, Inc.
709 S. Byrkit Ave.
Mishawaka IN  
Phone 5742571665
Email [email protected]
Designer Information
Patrick Leavell
Alliance Architects
929 Lincolnway East
South Bend IN  
Phone 5742882052
Email [email protected]
Project Information
Ceres Partners Office
806 Howard St.
South Bend IN 46617
County ST JOSEPH
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5742359554 Email: [email protected]
Local Fire Official 
5742359554 Email: [email protected]
Phone:

Variance Details
Code Name: ASME A17.1 2007
5.2.1.16.5
Conditions: Limited Use/Limited Application exceeds the maximum travel of 25'-0" (existing travel is 36'- 6") as outlined in Section 5.2 ASME A17.1 2007 #5.2.1.16.5
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The elevator is being provided as a convenience to our tenants. It is not required by code. 
2. The building floor plates are very small for an office use (2,903 SF). This is due to the fact  that we are building upon an existing structure. The implication is that we expect the elevator  to be lightly used (as compared to a typical office building).
3. The bottom stop provides access to a basement which houses mechanical equipment and storage only. No staff workstations will be included on this floor level. 
4. The proposed travel distance of 36'6" is well within the manufacturer's limit of 50'-0". The  basement stop accounts for 11'4" of the proposed 36'-6" travel distance.
5. We understand that the LULA type of elevator is designed for precisely this type of  application.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Y Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: A hydraulic elevator is approximately twice the initial cost of a LULA. This difference is in the  range of $70,000.

A hydraulic elevator requires approximately three times the number of annual maintenance  visits as does a LULA.