Project Information
Guglielmino Player's Lounge
University of Notre Dame
NOTRE DAME IN 46556
County ST JOSEPH
Project Type New   Addition   Alteration Y Existing Y Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5746314200 Email: [email protected]
Local Fire Official 
Phone: 5746314200 Email: [email protected]

Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC, 1004.1.2, 1015.1
Conditions: The project involves renovation of the existing players lounge. The calculated occupant load  of the lounge and study room exceed 49
requiring 2 means of egress. The variance request is to permit a single means of egress  from
the room. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: Guglielmino Athletics Complex houses the football practice-week locker rooms, coaches'  offices and meeting rooms in addition to enhanced sports medicine, strength and  conditioning and weight room equipment for all Notre Dame student-athletes.The room  contains a significant amount of furniture and larger seating limiting the actual occupant load.
1.  The building is fully sprinklered.

2. The common path of travel from the room is approximately 53 feet, within the permitted 75
feet for an A Occupancy with a single means of egress.

3. The room will be posted for a maximum occupant load of 49. Sec. 1004.1.2, exception, 2012  International Building Code (exception deleted by Indiana amendment), permits the design  occupant load to be reduced "where approved by the building official".

4. A similar variance was granted at Notre Dame for Lyons Hall Renovation , 13-06-36 and  Morrissey Hall 18-05-59. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The space has been in use for 10 years and historically does not comfortably accommodate  more that 25 persons.  The calculated occupant load of 93 is excessive for the space.