Owner / Applicant Information
John Trout
Concord Community Schools
59040 MINUTEMAN WAY
ELKHART IN 46517
Phone 5748755161
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianapolis IN  
Phone 3173297700
Email [email protected]
Designer Information
Dana Wannemacher
Barton Coe Vilamaa
225 Airport North Park
Fort Wayne IN  
Phone 2604899079
Email [email protected]
Project Information
Concord High School Fitness Addition
59117 Minuteman Way
Elkhart IN 46517
County ELKHART
Project Type New   Addition Y Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5742945471 Email: [email protected]
Local Fire Official 
5742945471 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
3311.2, 2014 IFC
Conditions: The proposed fitness addition will impact means of egress from the existing locker room in  the existing building during the time of construction.

An exterior door used as a means of egress from the locker room will be closed during  construction.

 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
 
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The locker room has a calculated occupant load of 42, permitting a single means of  egress.  A single means of egress will be maintained during construction.  The door in  question will be restored to use upon completion of the project. 

2. Sec. 3311.2, exception, IFC, states that approved temporary means of egress systems
and facilities may be provided during construction.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule would hamper construction by maintaining use of the door in question,  and also pose risk to students by allowing access through an area under construction.

Variance Details
Code Name:  Other Code (Not in the list provided)
706, 2014 IBC
Conditions: The 1-story fitness addition will be separated from the existing school building with a 2-hour  fire barrier in lieu of a fire wall. 

The addition will have 13,590 sq ft.  The addition will include a weight training area, cardio  area, rest rooms, and a small number of offices. The addition will be classified as E  Occupancy and Type IIB Construction.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The fire barrier will consist of the cmu + brick exterior wall of the existing building.

2. 90-minute rated doors will be provided in the separation.

3. The addition will be structurally independent of the existing building.

4. The addition will be protected throughout with an automatic sprinkler system.

5. An identical variance was granted for another addition to this school in April of this year -  18-04-36. Other very similar variances have been granted for additions to schools over the  past 20+ years, including recently 18-02-49b, 17-10-30a, 17-02-49, 17-01-26, 16-10-33c, 16- 06-10c, 16-01-14, 15-10-29c, and 15-04-51b.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Providing a structurally stable fire wall to separate the addition would add significant cost to  the project without providing any significant benefit to safety.