Owner / Applicant Information
Gary   Ratcliff
The Barn 
9950 US 231 S. 
LAFAYETTE IN 47909
Phone 7655869485
Email [email protected]
Submitter Information
Melissa  Tupper
RTM Consultants, Inc.
6640 Parkdale Place
Indianapolis IN  
Phone 3173297700
Email [email protected]
Designer Information
Andrew  Switzer
ARKOR Architects & Engineers
117 N. 4th Street
Lafayette IN  
Phone 3154294070
Email [email protected]
Project Information
Ratcliff Barn
9950 US 231 S.
Lafayette IN 47909
County TIPPECANOE
Project Type New   Addition   Alteration   Existing   Change of Occupancy Y
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order?    
Violation Issued by: NA
Local Building Official
Phone: 7654239225 Email: [email protected]
Local Fire Official 
7654239225 Email: [email protected]   
Phone:


Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC, Table 1014.3,505.2.2
Conditions: The travel distance from the existing mezzanine is approximately 110 feet. Code limits the  common path of travel from a mezzanine with a single means of egress in a S Occupancy to  100 feet.   

The project involves the conversion of an existing barn, Class 2 structure, to an event space. The building is classified as an A-2/S-1 Occupancy. The building is 1-story with mezzanine  and Type VB Construction. The 1st floor is 5,090 square feet with a mezzanine that is 840  square feet.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. A fire alarm system in accordance with Section 907, IBC will be installed throughout the  building.

2. Smoke detection will be provided throughout the building which is tied to the fire alarm  system.

3. The mezzanine is not used by the public, and will be blocked off during events. The  mezzanine is used for storage for the barn owner and it open to the rest of the barn. 

4. Based upon the mezzanine not being used by the public and the fire alarm and smoke  detection system, the travel distance from the existing mezzanine is not adverse to safety. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: It is a cost hardship for the owner to provide an additional stair from the existing mezzanine  that will not be occupied by the public and is used for the owners personal storage. The  mezzanine is open to the rest of the barn, making a fire readily apparent to the owner of the  barn. A fire alarm and smoke detection system will be provided throughout the building. 
Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IBC, 3401.1
Conditions: The project involves the conversion of an existing barn, Class 2 structure, to an event space. The variance request is to permit the building to be evaluated using Ch 34. 

The building is classified as an A-2/S-1 Occupancy. The building is 1-story with mezzanine  and Type VB Construction. The 1st floor is 5,090 square feet with a mezzanine that is 840  square feet.

DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. A structural evaluation has been completed for the proposed building for compliance with  Ch 16, see attached structural review from the engineer.

2. A fire alarm system installed in accordance with Section 907, IBC will be installed  throughout the building.

3. Smoke detection will be provided throughout the building which is tied to the fire alarm  system.

4. A shunt will be provided so that when the fire alarm is activated any music will be turned off,  this is not required by code. 

5. The maximum travel distance from the 1st floor to an exit is approximately 58 feet, code  permits 200 feet.

6. 3 exits directly to the exterior have been provided from the banquet hall assembly room.  The calculated occupant load of the building is 316 occupants. Code only requires 2 exits  based upon the calculated occupant load. 

7. The clear exit width to be provided from the banquet hall assembly room is 96" which will  accommodate and occupant load of 480. Code only requires 63.2" to be provided for an  occupant load of 316. 

8. There will be no open flames. 

9. Decorative lighting will be commercial grade and UL listed.

10. Decorative materials will be fire retardant treated.

11. Similar variances have been granted for Variance 17-09-61, The Legacy Barn; 17-08-45,  Salomon Farm Equipment Barn; 17-08-43, Salomon Farm Heritage Barn; 17-06-65, Coffee  Creek Ridge Event Barn; 17-01-16, Whippoorwill Hill Farm Event Barn; Variance 16-04-08,  Junken Wedding Barn; 15-12-25, Fenneman Wedding Barn; 15-06-49, The Barn of Coatesville; and 15-09-29, The Loft at Walnut Hill Farm.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule would prevent the use of the structure for the proposed use. Given  compliance with all applicable rules, the proposed conversion will not be adverse to safety.