Project Information
Marq
101 Main Street
LAFAYETTE IN 47901
County TIPPECANOE
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No yes
Violation Issued by: LFD
Local Building Official
Phone: 7658071000 Email: [email protected]
Local Fire Official 
7658071000 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
714.4, 2014 IBC
Conditions: Electrical cable penetrations of floors are not either within a fire-rated shaft, nor can tested  firestop assemblies protect the penetrations based upon the configuration of the as-built  condition.
The project scope is construction of a 4-story Type VA apartment structure on top of a 1- story plus basement Type IA podium structure used as a parking garage.  There is also a  connected 2-story bank branch building of Type IIB Construction.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  An alternative system of protection will be developed based upon adaptation of similar  firestop assemblies and materials.

2.  The building is protected with an automatic sprinkler system. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Given the progress of construction, it is not feasible at this point in time to identify a listed  assembly to remedy the as-built condition.  Areas identified on the plans to be used as fire- rated shafts were not constructed as fire-rated shafts.  The penetrations must now be treated  as floor penetrations.