Project Information
STEM Teaching Lab
XXXX N. University St
West Lafayette IN 47907  -   
County TIPPECANOE
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3174176651 Email: [email protected]
Local Fire Official 
3174176651 Email: [email protected]
Phone:

Variance Details
Code Name: 2014 IBC
1022.5
Conditions: In addition to the required swinging exit door(s) into and out-of  the exit enclosure, a fire- rated rolling door will also be installed at the basement, second, third, and fourth floor levels.  Section 1022.5 does not allow a door opening(s) other than the required exit door(s) within  an exit enclosure.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The proposed rolling fire-doors within exit enclosure will be three-hour motorized door  assemblies with UL smoke seals.  The rolling fire- door(s) will be automatic closing upon  smoke detection at the floor level entrance to the enclosure per the Indiana Building Code.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: The fire-rated rolling door(s) opening into the two hour fire-rated exit enclosure will allow  more open passage and regular use of the stairway.  It is the opinion of Purdue University that the alternatives provide an acceptable level of safety.