Owner / Applicant Information
Kevin Batman
Wesleyan Investment Foundation
13300 OLIO ROAD
FISHER IN 46037
Phone 3177749341
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianapolis IN  
Phone 3173277700
Email [email protected]
Designer Information
Gary Alexander
Gary Alexander, Architect
1306 South Valhalla
Upland IN  
Phone 7405412712
Email [email protected]
Project Information
Wesleyan Investment Foundation Tenant Space
13300 Olio Road
Fishers IN 46037
County HAMILTON
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3175953120 Email: [email protected]
Local Fire Official 
3175953120 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
1018.4, 2014 IBC
Conditions: The 3rd floor egress corridor will have a dead of approximately 59 feet due to a proposed  tenant reconfiguration.  Code limits a dead end to 50 feet in a Business Occupancy.
The project involves construction of a new tenant demising wall to create a separate tenant  on the south end of the 3rd floor.  The building is classified as B Occupancy and Type IIB  Construction.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The building is protected throughout with an automatic sprinkler system per NFPA 13.
2.  The corridor has a minimum width of 12 feet, significantly exceeding the minimum required  width of 44 inches.
3.  The tenant space which opens directly into the dead end has access to 3 exits from the  3rd floor.  Exit arrangement is such that all tenants have access to at least 2 exits.  
4.  Egress signage will be modified as necessary to accommodate the new plan  arrangement.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule would require closing off the common rest rooms from the rest of the  corridor, which would not provide any benefit to safety.