Owner / Applicant Information
Hemang  Shah
 
3201 INTERSTATE DR
EVANSVILLE IN 47715
Phone 8126617836
Email [email protected]
Submitter Information
Tera King
 
6630 Frito Lay Dr.
Evansville IN  
Phone 8124548072
Email [email protected]
Designer Information
DAVID HENSON
ARCHITECTURAL DESIGN CONCEPTS LLC
405 N. Nettleton Ave.
SPRINGFIELD MO  
Phone 8664446926
Email [email protected]
Project Information
Days Inn Jasper
272 Brucke Strasse
Jasper IN 47546
County DUBOIS
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3172322318 Email: [email protected]
Local Fire Official 
3172322318 Email: [email protected]
Phone:

Variance Details
Code Name: ASME A17.1 2007
3.19.4.5
Conditions: PRESSURE GAUGE FITTINGS: A PRESSURE GAUGE FITTING WITH SHUTOFF VALVE SHALL BE  PROVIDED ON JACK SIDE OF THE CHECK VALVE OR IMMEDIATELY ADJACENT TO THE  HYDRAULIC CONTROL VALVE. WHERE THE HYDRAULIC MACHINE IS LOCATED IN THE  HOISTWAY, THE PRESSURE GAUGE FITTINGS SHALL ONLY BE ACCESSIBLE T OTHE  ELEVATOR PERSONNEL FROM OUTSIDE THE HOISTWAY
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: THE MRL WILL BE INSTALLED IN A HOTEL TO PROVIDE HANDICAP CUSTOMER/STAFF TO HAVE ACCESS TO ALL FLOORS AT THE HOTEL.ALONG WITH THERE BEING MULTIPLE LEVELS THIS  IS ACCESSIBLE TO THOSE WITHOUT A DISABILITY ALSO.

Variance Details
Code Name: ASME A17.1 2007
3.19.4.1
Conditions: A MANUALLY OPERATED SHUTOFF VALVE SHALL BE PROVIDED BETWEEN THE HYDRAULIC  MACHINES AND  THE HYDRAULIC JACK AND SHALL BE LOCATED OUTSIDE THE HOISTWAY  AND ADJACENT TO THE HYDRAULIC MACHINE. WHERE THE HYDRAULIC MACHINE IS LOCATED IN THE HOISTWAY, THE MANUALLY OPERATED SHUTOFF VALVE SHALL BE PERMITTED TO BE LOCATED INSIDE THE HOISTWAY, PROVIDED THAT IT IS ACCESSIBLE FROM OUTSIDE THE  HOISTWAY TO THE ELEVATOR PERSONNEL ONLY
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: THE MRL WILL BE INSTALLED IN A HOTEL TO PROVIDE HANDICAP CUSTOMER/STAFF TO HAVE ACCESS TO ALL FLOORS AT THE HOTEL.ALONG WITH THERE BEING MULTIPLE LEVELS THIS  IS ACCESSIBLE TO THOSE WITHOUT A DISABILITY ALSO.