Owner / Applicant Information
Jack Ventimiglia
DFG- LaPorte,LLC
10100 WATERVILLE ST.
WHITEHOUSE OH 43571
Phone 2484069172
Email [email protected]
Submitter Information
James Horsch
Herschman Architects, Inc
25001 Emery Road
Cleveland IN  
Phone 2162233216
Email [email protected]
Designer Information
Dushan Bouchek
Herschman Architects, Inc.
25001 Emery Rd.
Cleveland OH  
Phone 2162233200
Email [email protected]
Project Information
Ollie's Bargain Outlet
71A Pine Lake Ave
LAPORTE OH 46350
County LAPORTE
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 2193622327 Email: [email protected]
Local Fire Official 
2193622327 Email: [email protected]
Phone:

Variance Details
Code Name: 675 IAC 12-4-12(f)
2014Indiana B.C. section 503.1
Conditions: The existing shopping center doesn't meet the current code; it was built in 1989.  And the  addition of the small truck service enclosure adds to the non-compliance.  Under the current code, it's not an unlimited area building (507)  because it is not fully sprinklered &  surrounded by open public ways 40 or 60' wide.  It is not a separated mixed use building  (508) because it doesn't meet the sum of the ratios provision.  It cannot be considered  separate buildings on the same lot (503.1.2) because there are no known fire walls in use. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
2
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: The alternative action is to create a new 'fire area' for the non-sprinklered stock room by  adding 3 hour rated  'fire barrier' assemblies to both demise walls.  As a new 'fire area', the  alteration will make the building more safe than currently exists.  The 400sf truck service  enclosure (addition) is open air like a canopy and all steel & aluminum construction and  therefore has a negligible impact to the over-all area non-compliance. 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
Y
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: The only way to make the shopping center compliant with current code would be to construct  fire walls, thereby making separate buildings that meet the area limitations.  Adding fire walls:
-Imposes major disruption of the building structure to build the walls.\
-Imposes major operational problems with use because it takes up additional square footage  altering existing occupied tenant spaces.
-Imposes excessive costs due to the two reasons above.