Owner / Applicant Information
George Boyd
Avery Dennison
870 ANDERSON BOULEVARD
GREENFIELD IN 46140
Phone 3174676947
Email [email protected]
Submitter Information
Edwin Rensink
RTM Consultants Inc
6640 Parkdale Place
Indianapolis IN  
Phone 3173297700
Email [email protected]
Designer Information
Harold Force, PE
Force Design Inc.
990 North National Road
Columbus IN  
Phone 8123728441
Email [email protected]
Project Information
Avery Dennison Addition
870 Anderson Boulevard
Greenfield IN 46140
County HANCOCK
Project Type New   Addition Y Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3174774320 Email: [email protected]
Local Fire Official 
3174774320 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
1016.2, 2014 IBC
Conditions: Egress travel distance from a portion of the existing building will exceed the permitted 250  egress travel distance to an exit as a result of the proposed building addition.  The existing  building is 297,631 sq ft in floor area, and the addition will be 292,162 sq ft in floor area.
The building is classified as F-1 Occupancy, with accessory B Occupancy and an  accessory A-3 Occupancy space.  Avery Dennison manufactures and distributes labeling  and packaging materials.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1.  The maximum travel distance will not exceed 400 feet. In the 2015 and the 2018 IBC, a  maximum travel distance of 400 feet is permitted from F-1 Occupancies protected throughout  with an automatic sprinkler system where the ceiling is 24 feet or more in height.  The actual  ceiling height varies from 34'5" to 49'.
2.  The building is protected throughout with an automatic sprinkler system.  The addition,  through which egress will pass from portions of the existing building, will be protected with an  ESFR sprinkler system in the high- and low-bay portions of the plant area.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Imposition of the rule would require a fire barrier to separate the addition from the existing  building - which cannot feasibly be accomplished due to the placement of manufacturing  equipment in the building.