Owner / Applicant Information
nieto marie
KONE Inc
1080 PARKVIEW BOULEVARD
LOMBARD IL 60148
Phone 6306293100
Email [email protected]
Submitter Information
Marie  Nieto
KONE Inc.
1080 Parkview Boulevard
Lombard IN  
Phone 6306293100
Email [email protected]
Project Information
Cancer Treatment Center
701 Superior Avenue
Munster  IL 46321
County LAKE
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order?    
Violation Issued by: NA
Local Building Official
Phone: 2198366961 Email: [email protected]
Local Fire Official 
Phone: 2198366961 Email: [email protected]

Variance Details
Code Name: ASME A17.1 2007
2.20.4
Conditions: New KONE Ecospace elevator will use 6mm - 8mm ropes on elevator in lieu of the 9.5 mm  diameter.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: KONE to provide 6mm and 8mm suspension cables as the technology of he Ecospace  elevator 2007 Edition. The technology of the Ecospace elevator is new and not addressed by  ASME A17.1 2007 Edition. The installation does comply with 2004/2005 Supplements to ASME  A17.1 (ASME A17.1 2005).
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: This elevator application deletes the need to build an elevator penthouse therefore lowering  overall building costs. The elevator technology is addressed by and complies with more  recent elevator standard not currently adopted by the State of Indiana.