Project Information
DEACONESS GATEWAY HOSPITAL
4011 GATEWAY BLVD
NEWBURGH IN 47630
County WARRICK
Project Type New Y Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 8124314391 Email: [email protected]
Local Fire Official 
8124314391 Email: [email protected]
Phone:

Variance Details
Code Name: ASME A17.1 2007
3.19.4.5
Conditions: PRESSURE GAUGE FITTINGS-A PRESSURE GAUGE FITTING WITH SHUTOFF VAKVE SHALL BE  PROVIDED ON JACK SIDE OF THE CHECK VALVE OR IMMEDIATELY ADJACENT TO THE  HYDRAULIC CONTROL VALVE. WHERE THE HYDRAULIC MACHINE IS LOCATED IN THE  HOISTWAY PRESSURE GAUGE FITTINGS SHALL ONLY BE ACCESSIBLE TO ELEVATOR  PERSONNEL FROM OUTSIDE THE HOISTWAY
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: THE MRL WILL BE INSTALLED IN A HOSPITAL TO PROVIDE HANDICAP PATIENTS/STAFF TO  HAVE ACCESS TO ALL FLOORS AT THE HOSPITAL

Variance Details
Code Name:  Other Code (Not in the list provided)
3.19.4.4
Conditions: MANUAL LOWERING VALVE-A MANUALLY OPERATED VALVE,LOCATED ON OR ADJACENT TO  THE CONTROL VALVES, SHALL BE PROVIDED AND IDENTIFIED, WHICH PERMITS LOWERING  THE CAR AT A SPEED NOT EXCEEDING 0.10 M/S (20FT/MIN). THIS VALVE SHALL BE SO  MARKED TO INDICATE THE LOWERING POSITION. WHERE THE HYDRAULIC MACHINE IS  LOCATED IN THE HOISTWAY,THE MANUAL LOWERING VALVE SHALL ONLY BE ACCESSIBLE  TTO THE ELEVATOR PERSONNEL FROM OUTSIDE THE HOISTWAY.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: THE MRL WILL BE INSTALLED IN A HOSPITAL TO PROVIDE HANDICAP PATIENTS/STAFF TO  HAVE ACCESS TO ALL FLOORS AT THE HOSPITAL.
Variance Details
Code Name:  Other Code (Not in the list provided)
3.19.4.1
Conditions: SHUTOFF VALVE- A MANUALLY OPERATED SHUTOFF VALVE SHALL BE PROVIDED BETWEEN  THE HYDRAULIC MACHINES AND THE HYDRAULIC JACK AND SHALL BE LOCATED OUTSIDE  THE HOISTWAY AND ADJACENT TO THE HYDRAULIC MACHINE. WHERE THE HYDRAULIC  MACHIN IS LOCATED IN THE HOISTWAY,THE MANUALLY OPERATED SHUTOFF VALVE SHALL  BE PERMITTED TO BE LOCATED INSIDE THE HOISTWAY, PROVIDED THAT IT IS ACCESSIBLE  FROM OUTSIDE THE HOISTWAY TO ELEVATOR PERSONNEL ONLY.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 

THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
 
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: THE MRL WILL BE INSTALLED IN A HOSPITAL TO PROVIDE HANDICAP PATIENTS/STAFF TO  HAVE ACCESS TO ALL FLOORS AT THE HOSPITAL.

Variance Details
Code Name:  Other Code (Not in the list provided)
3.26.8
Conditions: PRESSURE SWITCH-WHEN CYLINDERS ARE INSTALLED WIT THE TOP OF THE CYLINDER  ABOVE THE TOP OF STORAGE TAKE,A PRESSURE SWITCH SHALL BE PROVIDED IN THE LINE  BETWEEN THE CYLINDER AND THE VALVE, WHICH SHALL BE ACTIVATED BY THE LOSS OF  POSITIVE PRESSURE AT THE TOP OF THE CYLINDER. THE SWITCH SHALL PREVENT  AUTOMATIC DOOR OPENING AND THE OPERATION OF THE LOWERING VALVE OR  VALVES.THE DOOR(S)SHALL BE PERMITTED TO OPEN BY OPERATION OF THE IN CAR  BUTTON. WHEN THE CAR IS WITHIN THE UNLOCKING ZONE.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: THE INSTALLATION OF A MRL WILL SAVE ENERGY; NO INGROUND JACK PUSHING OIL TO THE  UNIT ALL IS IN THE HOISTWAY PROVIDING A SPECIFIC VALVE THAT ONLY OUR ELEVATOR  MECHANICS WILL HAVE ACCESS TO.
MRL WILL NOT BE OF ANY THREAT OR WILL BE UNSAFE IN REGARDS TO THE VARIANCE  BEING APPLIED.
.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: THE MRL WILL BE INSTALLED IN A HOSPITAL TO PROVIDE HANDICAP PATIENTS/STAFF TO  HAVE ACCESS TO ALL FLOORS AT THE HOSPITAL