Owner / Applicant Information
Kanagy Eric
Pizzeria Venturi, LLC
119 E LINCOLN AVE.
GOSHEN IN 46528
Phone 5748498881
Email [email protected]
Submitter Information
Carrie Ballinger
RTM Consultants, Inc.
6640 Parkdale Place, Ste J
Indianapolis IN  
Phone 3173297700
Email [email protected]
Designer Information
DOUGLAS L GRAHAM
Barr Design Group, LLC
502 S Main St.
Goshen IN  
Phone 5745346531
Email [email protected]
Project Information
Pizza Venturi LLC Remodel
119 E Lincoln Ave
GOSHEN IN 46528
County ELKHART
Project Type New   Addition   Alteration Y Existing   Change of Occupancy Y
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 5745341811 Email: [email protected]
Local Fire Official 
5745341811 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
2014 IMC Sec. 507.2
Conditions: A site-built wood-fired bread oven will not have a Type I hood. 

The project involves remodel and conversion of an existing 1st floor tenant space with a new  commercial kitchen.  The kitchen area is a single story and is separated from the rest of the  building with a 2-hour fire barrier. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The oven uses natural draft ventilation with a chimney rather than a hood system. 
2. The oven will only be used for bread-baking and will not produce grease-laden vapors.
3. Removing the direct vent and installing a Type I hood may decrease the safety of the  installation.  The high temperatures inside the oven could cause creosote to quickly build up  in the exhaust duct, increasing the fire hazard.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
 
Facts: Imposition of the rule will result in excessive cost of installing a hood system as well as  potential decreased fire safety.  The direct vent method is commonly used on wood-fired  ovens.