Owner / Applicant Information
Jefferson Shreve
Storage Express Holdings, LLC
P.O. BOX 70
BLOOMINGTON IN 47402
Phone 8123396339
Email [email protected]
Submitter Information
Patrick Riley
Storage Express Construction, LLC
P.O. Box 70
Bloomington IN  
Phone 8123320110
Email [email protected]
Designer Information
JERRY GENE HOFFMAN
U S Architects
9200 West Smith Road
Yorktown IN  
Phone 7654051220
Email [email protected]
Project Information
Storage Express - Madison Avenue
7634 Madison Avenue
Indianapolis IN 46227
County MARION
Project Type New   Addition   Alteration   Existing   Change of Occupancy  
Project Status F F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3173278700 Email: [email protected]
Local Fire Official 
3173278700 Email: [email protected]
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
Section 1809.5 Frost Protectio
Conditions: Project will use floating slab foundations. Foundations will not extend below frost line.
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or w
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: Foundations as designed have been used historically in many other storage facilities without  adverse affect on the public.
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty)  because of physical limitations of the construction site or its utility services.
 
  Imposition of the rule would result in an undue hardship (unusual difficulty)  because of major operational problems in the use of the building or structure.
Y Imposition of the rule would result in an undue hardship (unusual difficulty)  because of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an  architecturally or a historically significant part of the building or structure
Facts: Entire concrete slab sits on a layer of free draining granular fill.  The design and uniform  loading should allow more uniform displacement if heave occurs, resulting in less stress on  the foundation and structure.  See attached letter from Trachte Building Systems.