Owner / Applicant Information
Michelle Bodem
United Technologies Carrier
7310 WEST MORRIS STREET
INDIANAPOLIS IN 46231
Phone 3174815743
Email MICHELLE.BODEM@CARRIER.UTC.COM
Submitter Information
Dennis Bradshaw
Fire Protection & Code Consultants, LLC
1520 Main Street
Indianapolis IN  
Phone 3174865188
Email DBradshaw@FPC-Consultants.com
Designer Information
Scott Jones
ARSEE Engineers
9715 Kincaid Dr., Suite 100
Fishers IN  
Phone 3175945152
Email sjones@arsee-engineers.com
Project Information
Carrier Warehouse Wall
7310 West Morris Street
Indianapolis IN 46231
County MARION
Project Type New   Addition   Alteration Y Existing   Change of Occupancy  
Project Status U F=Filed U or Null=Unfiled
IDHS Issued Correction order? No No
Violation Issued by: NA
Local Building Official
Phone: 3173274104 Email: planreview.class1@indy.gov
Local Fire Official 
3173274104 Email: Margie.Bovard@indy.gov
Phone:

Variance Details
Code Name:  Other Code (Not in the list provided)
1016.2, Table 1016.2, 2014 IBC
Conditions: An existing fully sprinklered manufacturing  facility will have some areas with egress travel  distance of 395 feet. The code allows a maximum of 250 feet travel distance in a fully  sprinklered building. A variance was previously granted for a travel distance of 395 feet, but a  new proposed wall will cause the egress routing to change, but still within the 395 feet limit. 
DEMONSTRATION THAT PUBLIC HEALTH, SAFETY, AND WELFARE ARE PROTECTED:
1=Non-compliance with the rule will not be adverse to the public health, safety or we
1
2= Applicant will undertake alternative actions in lieu of compliance with the rule to  ensure that granting of the variance will not be adverse to public health, safety, or  welfare.  Explain why alternative actions would be adequate (be specific).
Facts: 1. The existing building is protected with an automatic fire suppression system per NFPA 13.
2. The building is a high bay structure (24' above the floor to the deck). Accumulation of smoke  in this area above the floor will allow occupants sufficient egress from the building.
3. Occupants will be manufacturing personnel who are familiar with the equipment layout and  the path of egress. 
4. The facility is used for the manufacturing of air conditioning and refrigeration units and will  have a limited amount of combustible materials.  
DEMONSTRATION OF UNDUE HARDSHIP OR HISTORICALLY SIGNIFICANT STRUCTURE:
Imposition of the rule would result in an undue hardship (unusual difficulty) because  of physical limitations of the construction site or its utility services.
 
Imposition of the rule would result in an undue hardship (unusual difficulty) because  of major operational problems in the use of the building or structure.
 
Y Imposition of the rule would result in an undue hardship (unusual difficulty) because  of excessive costs of additional or altered construction elements.
  Imposition of the rule would prevent the preservation of an architecturally or a historically significant part of the building or structure.
Facts: The owner's undue hardship is the desire to provide a wall between the manufacturing area and storage area and the fact that the proposed wall causes a rerouting of the current egress paths.