DHS

Indiana Department of Homeland Security / Fire and Building Safety Division

2019-20 version

 

Variance Application(s)



Steps:
1. First search for the type of variances to be displayed using search options.
2. Use Sort buttons to sort the variances.
3. For old variances, select Processed Applications along with dates.

Search for Applications

Fill these options below if you select **Processed applications option above in the list box above.
To get best response times narrow down search criteria recommended
Example search for a county or search for a 3 month time period with owner name like.,

Enter Variance Number
Enter Project Name like Example for Eli Lilly just enter lilly in the text box
** Enter Application From Date mm/dd/yyyy
** Enter Application To Date     mm/dd/yyyy
** Enter County Name
** Enter Code Type


Use Arrow buttons to sort the results by the column name.

Staff Recommendations Notations Explanation:
"A" category = staff recommendation is for approval with no equal alternatives because of noncompliance is not adverse. "B" category = staff recommendation is for approval with equal alternatives as stated by the proponent. "C" category = reserved, meaning staff believes Commission needs to discuss entirety. "D" category = recommendation is for denial. "I" category = incomplete (with permission of the Chairman). "NVR" category = no variance required. "T" category = tabled.
Variance Number/Id
Project Name
County
Variance Codes
18463 (Online)
Application Date:04/10/2018
Name Porcelain pavers flame test report.pdf  Date:04/10/2018
Name GWI64.PDF  Date:04/10/2018
Name grillworks_infierno_52_64_80_installationanduse_final_sd.pdf  Date:04/10/2018
Name Grillworks_Guide_2016.pdf  Date:04/10/2018
Bridges Wine Bar  19 N. Indiana Street 
Greencastle 46135  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
PUTNAM 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IFC 308.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18463 The code prohibits any occupancy other than Group R-2, R-3, and R-4 occupancies from having open flame devices on the premises. The request is to allow an existing A-2 occupancy restaurant to have a new wood or charcoal burning grill on the roof top dining area. Building is sprinklered including conditioned spaces on the roof, fire alarm system is included on the roof area, main frame of the grill is constructed of 16 gauge steel, side and bottom is constructed of 14 gauge and back plate is 7 gauge. Solid fuel is placed on a fire cage. Grill will not be utilized if weather conditions forecast storms or winds exceeding 15 MPH. 
18496 (Online)
Application Date:04/24/2018
Name TESTING Lantern (1).pdf  Date:04/24/2018
Name sky-lantern-sds-us.pdf  Date:04/24/2018
The Lights Fest  2581 IN-2, La Porte, IN 46350 
La Porte 46350  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
LAPORTE 
Code Name:2014 IBC [view code Details]
Specific Section:

Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:18496 INCOMPLETE - Completion of boxes 
18497 (Online)
Application Date:04/26/2018
Name Architectural 397854.pdf  Date:04/26/2018
St. Louis Besancon Catholic Church  15535 Lincoln Hwy E. 
New Haven 46774  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name:2014 IFC [view code Details]
Specific Section:
Fire Code Section 1015.1.1
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:18497 WITHDRAWN BY PROPONENT 05/02/18. 
18500 (Online)
Application Date:05/03/2018
Name Express_Town Square Shopping Center.pdf  Date:05/03/2018
Express  Town Square Shopping Center 
Schererville 46321  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
LAKE 
Code Name:2010 Indiana Energy Conservation Code (675 IAC 19-4) [view code Details]
Specific Section:
5.4.3.4
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18500 The code permits a vestibule to be omitted from a building entrance if the space served by the door is less than 3,000 sq. ft. The request is to allow the vestibule to be omitted in the 7,011 S.F. building. Door opens up to 5,707 sq. ft. Proponent states all codes for fresh air intake and exhaust are satisfied.  
18530 (Online)
Application Date:05/14/2018
Name scan0027.pdf  Date:05/14/2018
Name scan0033.pdf  Date:05/21/2018
Bobbys Convenience Store  2217 W Franklin 
ELKHART 00000  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
ELKHART 
Code Name:2010 Indiana Energy Conservation Code (675 IAC 19-4) [view code Details]
Specific Section:
ASHRAE PARA 5.4.3.4
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:18530 WITHDRAWN BY PROPONENT 05/21/18. 
18538 (Online)
Application Date:05/15/2018
removal of old fire door  4404 Engle Ridge drive 
Fort Wayne  46804  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
ALLEN 
Code Name: [view code Details]
Specific Section:
703.2
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:18538 INCOMPLETE -COMPLETION OF BOXES, code, edition, owner, LFO 
18636 (Online)
Application Date:06/15/2018
Name Tire Discounters Example Sheets.pdf  Date:06/15/2018
Tire Discounters   375 South Perry Road 
Plainfield  46168  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
HENDRICKS 
Code Name:2014 IFC [view code Details]
Specific Section:
903.2.9.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18636 Withdrawn by Proponent 
18643 (Online)
Application Date:06/29/2018
Name H-MRL Code Deviations.pdf  Date:06/29/2018
CEDIA Headquarters  Kincaid Dr 
FISHERS 46037  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
HAMILTON 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.26.8 ASME A17.1 2007
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18643 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
18645 (Online)
Application Date:06/29/2018
Name H-MRL Code Deviations.pdf  Date:06/29/2018
FOH Fairfield Inn & Suites  708 N 600 E 
Fair Oaks 47943  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
JASPER 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
3.26.8 ASME A17.1 2007
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18645 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
18680 (Online)
Application Date:07/17/2018
IU Health North Cancer Center expansion  11700 N Meridian St. 
Carmel 46032  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name:2009 Indiana Electrical Code (675 IAC 17-1.8) [view code Details]
Specific Section:
Section 700.27
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18680 WITHDRAWN BY PROPONENT 07/26/18. 
18713 (Online)
Application Date:07/25/2018
Name Variance Information for ropes.pdf  Date:07/25/2018
The Rise at Chauncey  100 S. Chauncey Ave. 
West Lafayette 47906  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
TIPPECANOE 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
2.20.4, 2.20.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18713 8 mm ropes will be used in lieu of the required minimum diameter of 9.5mm.  
18722 (Online)
Application Date:08/07/2018
Name H-MRL Code Deviations.pdf  Date:08/07/2018
Heritage Woods of Noblesville  9600 E. 146th St. 
Noblesville   [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
HAMILTON 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18722 (a) MRL Technology 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
18724 (Online)
Application Date:08/09/2018
Name 03_AL-101-AL-101.pdf  Date:08/09/2018
Name 10_A-101-A-101.pdf  Date:08/09/2018
Name 24_AQ-101-AQ-101.pdf  Date:08/09/2018
Name Consultant Consent Form - signed.pdf  Date:08/09/2018
Caseys General Stores  116 National Rd W. 
RICHMOND 47374  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO Notified!
LBO Notified!
WAYNE 
Code Name:2010 Indiana Energy Conservation Code (675 IAC 19-4) [view code Details]
Specific Section:
5.4.3.4
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:18724 INCOMPLETE - CLARIFICATION, LBO,LFO,DESIGNER. 
18767 (Online)
Application Date:08/14/2018
Avant(Grand and Main)  12852 Old Meridian St 
Carmel 46032  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 1008.1.9
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:Withdrawn by proponent 08/24/18. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 1008.1.9
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:Withdrawn by proponent 08/24/18.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 1004.1.2
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:Withdrawn by proponent 08/24/18.  
Code Name:2014 IBC [view code Details]
Specific Section:
Section 1008.1.9
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:Withdrawn by proponent 08/24/18.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IFC Sec. 3311.2
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:Withdrawn by proponent 08/24/18.  
18801 (Online)
Application Date:08/29/2018
Name H-MRL Code Deviations.pdf  Date:08/29/2018
Hamilton Heights SC Project Vision PH 1 MS  25150 SR 19 
ARCADIA   [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
HAMILTON 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18801 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
18809 (Online)
Application Date:09/05/2018
Name Cottage Mural Door.jpg  Date:09/05/2018
Auguste's Cottage Mural  762 N Dan Jones Rd 
Avon 46123  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:2008 Indiana Fire Code (675 IAC 22-2.4) [view code Details]
Specific Section:
Code 22-11-17-2
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:18809 INCOMPLETE - CODE EDITION, SECTION 
18813 (Online)
Application Date:09/08/2018
Name WHITE ROCK SUBMITTAL DWGS.pdf  Date:09/08/2018
White Rock Barn  6642 N State Rd 1 
OSSIAN 46777  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
WELLS 
Code Name:2014 IBC [view code Details]
Specific Section:
3401.1
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:18813 WITHDRAWN BY PROPONENT. 
18859 (Online)
Application Date:09/19/2018
Name 12931_A101.pdf  Date:10/25/2018
Connersville Congregation of Jehovah's Witnesses Renovation  3171 East SR 44 
Connersville 47331  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO Notified!
LBO Notified!
FAYETTE 
Code Name:2014 Indiana Fire Code [view code Details]
Specific Section:
907.2.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18859 The code requires a manual fire alarm system to be installed in Group A occupancy where the occupant load is 300 or more. The fire alarm system is to be monitored by an approved supervising station. The request is to have the monitored fire alarm system requirement omitted. Proponent states the maximum occupant load of the building is 180. What is the calculated occupant load?  
18861 (Online)
Application Date:09/28/2018
Name Petition Referral Form.pdf  Date:09/19/2018
Name 2314 Woodlawn - Permit Set (1).pdf  Date:09/28/2018
Name 2314 Woodlawn Class 2 Res Dev Permit Application Page 1.pdf  Date:09/28/2018
Name 2314 Woodlawn Class 2 Res Dev Permit Application Page 2.pdf  Date:09/28/2018
2314 Woodlawn Avenue  2314 Woodlawn Avenue 
Indianapolis 46203  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
MARION 
Code Name: [view code Details]
Specific Section:
Bdroom window egress spec shee
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:18861 WITHDRAWN BY PROPONENT 10/08/18. INCOMPLETE - CODE, EDITION, COMPLETION OF BOXES, CLARIFICATION 
18863 (Online)
Application Date:10/03/2018
Name Rope Certification.pdf  Date:10/03/2018
Name BKUP_6451965_10010_20181003032430.pdf  Date:10/03/2018
Name BKUP_6451965_10140_20181003032526.pdf  Date:10/03/2018
Name BKUP_6451965_10270_20181003032633.pdf  Date:10/03/2018
Midtown Parking Garage  Carmel 
Carmel 46032  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007, 2.20.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18863 (a) Kone EcoSpace Elevators will utilize 8mm steel wire rope suspension instead of the required minimum diameter of 9.5mm.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007, 2.18.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) KONE EcoSpace Elevators with a capacity of 3,000-5,000# will utilize 6mm steel wire governor rope instead of the required minimum diameter of 9.5mm. 
18879 (Online)
Application Date:10/10/2018
YMCA Downtown Development  222 NW 6th St. 
Evansville 47708  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
VANDERBURGH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18879 (a) MRL Technology. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) MRL Technology 
18881 (Online)
Application Date:10/12/2018
Duke Realty Headquarters  8711 River Crossing Blvd 
INDIANAPOLIS 46240  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
905.4 IBC 2014 Edition
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18881 The code requires hose connections to be located at an intermediate floor level landing between floors. The request is to allow the existing standpipes to have hose connections located at the main floor landings. Similar variances have been granted in the past.  
18897 (Online)
Application Date:10/16/2018
Woodspring Suites Merriville  1500 E. 83rd Street 
Merriville 46410  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
LAKE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007 Sec. 2.20.4
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18897 Withdrawn by proponent 11/29/18. All variances. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007Sec. 2.18.4.2.5

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007 Sec. 2.22.1.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1-2007 Sec. 2.18.5.1

18899 (Online)
Application Date:10/16/2018
Name Variance Application - State Project 400835 SET.pdf  Date:10/16/2018
IU Columbus Downtown Building Modifications  333 2nd St 
COLUMBUS 47201  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
BARTHOLOMEW 
Code Name:2008 Indiana Building Code (675 IAC 13-2.5) [view code Details]
Specific Section:
1008.1.9.3 Item 2
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:18899 INCOMPLETE - CODE EDITION, CLARIFICATION. 
18901 (Online)
Application Date:10/16/2018
TRK Medical Office Building  1425 Glendale Blvd. 
Valparaiso 46384  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
PORTER 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1, 2.22.1.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18901 (a) KONE is proposing to use polurethane buffers for this project until the 2016 becomes the standard for Indiana. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
A17.1-2007, 2.20.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) Kone will utilize 8mm steel wire rope instead of the required minimum diameter of 9.5mm.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
A17.1-2007, 2.18.5.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) KONE EcoSpace Elevators will utilize 8mm governor rope instead of the required minimum diameter of 9.5mm.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
A17.1-2007, 2.18.4.2.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(d) The code requires speed-reducing switch to be of the manually reset type. The request is to allow the governor switch to be reset remotely from the controller. 
18950 (Online)
Application Date:11/09/2018
Name SK-2 - SECOND FLOOR PLAN.pdf  Date:11/09/2018
Name Loft Ladder _ Telesteps.pdf  Date:11/09/2018
Hubbard Gardens  4004 Meadows Dr 
INDIANAPOLIS 46205  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
InMC - 2014 - Section 306.5
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:18950 The code requires permanent roof access to be installed when equipment or appliances requiring access is located on the roof of a building, such that the servicing personnel will have to climb higher than 16 feet above grade to access the equipment or appliances. A/C and condensing units are being located on the roof of the building. The request is to allow a telescoping ladder to be used in lieu of a fixed ladder. Proponent states, there is a roof access hatch, but due to the size of the existing landing, there is not enough room to provide a fixed ladder.  
18984 (Online)
Application Date:11/29/2018
Name 646832-Layout.pdf  Date:11/29/2018
Holiday Inn Express  10040 Diebold Rd 
FORT WAYNE 46825  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
ALLEN 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.20.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:18984 (a) Steel coated belts will be used as the suspension means.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.18.5.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) Two Gen2 elevators will utilize 6.3 mm governor rope instead of the required minimum diameter of 9.5mm.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.22.1.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) Two Gen2 elevators will use ACLA buffers in place of spring buffers.  
18991 (Online)
Application Date:12/03/2018
MDW Management LLC  300 Olive Street 
Wabash 46992  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
WABASH 
Code Name:2011 NFPA 25 Inspection, Testing and Maintenance of Water Based Fire Protection Systems (675 IAC 28-1-12) [view code Details]
Specific Section:

Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:INCOMPLETE - SECTION, Hardship 
Code Name:2010 NFPA 13 Installation of Sprinkler Systems (675 IAC 28-1-5) [view code Details]
Specific Section:
675 IAC 28-1-5 Section 6.5.2
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:INCOMPLETE - Wrong section 
Code Name:2008 Indiana Building Code (675 IAC 13-2.5) [view code Details]
Specific Section:
Section 10 Chapter 9

19040 (Online)
Application Date:12/17/2018
Name Elmwood Phase III - Bldg A - 2018-10-26.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG B - Complete Set.pdf  Date:01/04/2019
Name Elmwood Phase III - Bldg C - 2018-10-26.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG D - Complete Set.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG E - Complete Set.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG F - Complete Set.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG G - Complete Set.pdf  Date:01/04/2019
Name Elmwood Phase III - BLDG H - Complete Set.pdf  Date:01/04/2019
Name Elmwood 3 Site Plan.pdf  Date:01/04/2019
Elmwood Phase 3  2860 Hayward Ave 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 903.3.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19040 The code requires at least an NFPA 13R system to be installed in Group R occupancies (apartments) that are no more than 4-stories. The request is to allow an NFPA 13 D system to be used in a 1-story, 8 unit apartment building. Which building?  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 903.3.1.2
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
Code Name: [view code Details]
Specific Section:

Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
19041 (Online)
Application Date:12/17/2018
Name BLDG 3 Set - 2018-10-29.pdf  Date:01/04/2019
Name BLDGS 2, 5 Set - 2018-10-29.pdf  Date:01/04/2019
Name BLDGS 1, 4, 6 Set - 2018-10-29.pdf  Date:01/04/2019
Woodbury Ridge Phase 2  1192 Hamilton Way 
Westfield 46074  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 903.3.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19041 The code requires at least an NFPA 13R system to be installed in Group R occupancies (apartments) that are no more than 4-stories. The request is to allow an NFPA 13 D system to be used in a 1-story, 8 unit apartment building. Which building?  
19044 (Online)
Application Date:12/19/2018
Name H-MRL Code Deviations.pdf  Date:12/19/2018
Hendricks County Bank Offices  1 E. Main St. 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19044 (a) MRL Technology 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology 
19052 (Online)
Application Date:12/31/2018
Name EVSC - Construction Set V2.pdf  Date:12/31/2018
Name EVSC - Construction Set V2.pdf  Date:12/31/2018
Name North Elem School - Nature of non-compliance.pdf  Date:12/31/2018
Name North Elem School - Not adverse to HSW.pdf  Date:12/31/2018
Name North Elem School - Result in undue hardship.pdf  Date:12/31/2018
New Northside Elementary School  10701 Petersburg Road 
Evansville 47725  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
VANDERBURGH 
Code Name: [view code Details]
Specific Section:

Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
Code Name:1999 Indiana Electrical Code (675 IAC 17-1.5) [view code Details]
Specific Section:
300.10
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
Code Name: [view code Details]
Specific Section:

Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
Code Name: [view code Details]
Specific Section:


Code Name:2009 Indiana Electrical Code (675 IAC 17-1.8) [view code Details]
Specific Section:
300.10
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
19072 (Online)
Application Date:01/14/2019
Name Variance Request.pdf  Date:01/14/2019
Name [4] REVISED CONSTRUCTION DRAWINGS C-01 [4]-Model.pdf  Date:01/14/2019
Retail Development  4305 East Michigan St 
INDIANAPOLIS 46201  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:2014 IBC [view code Details]
Specific Section:
Section 1008.1.6 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19072 The code requires landings at doors to have a width not less than the width of the stairway or the door, whichever is greater. The request is to allow the required landing to be omitted. Proponent states the building is more than 80 years old and there is only 1.7 feet between the building and the right-of-way which does not provide enough space to construct a 44 feet deep landing. When the building was originally constructed, the floor line was placed approximately 10-12 inches above the adjacent sidewalk and a small step was placed at each entry. The step has since deteriorated and is being replaced with a new step with a deeper tread and with handrails. 
19083 (Online)
Application Date:01/15/2019
Name scan0115.pdf  Date:01/15/2019
Name scan0116.pdf  Date:01/15/2019
Name scan0117.pdf  Date:01/15/2019
Kulich Inn - New Building  12296 E. US HWY 50 
Seymour 47274  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
JACKSON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 903.2.8
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19083 The code requires at least an NFPA 13R sprinkler system to be provided in all buildings with a Group R fire area. The request is to allow an NFPA 13D system to be provided in the new 12 unit apartment building that is being constructed at an existing apartment complex replacing the existing 6 unit building. Proponent states the existing buildings are not sprinklered and was not required to be sprinklered. The 12 single bed units will all have direct access to exterior exit or exit balcony. 
19086 (Online)
Application Date:01/15/2019
Name 001AlarmBid.jpg  Date:01/15/2019
Name 002SprinklerBid.jpg  Date:01/15/2019
Name 003 BLDG Plan.jpg  Date:01/15/2019
Name 004 Purchase Price.jpg  Date:01/15/2019
Name 005 Improvement Price.jpg  Date:01/15/2019
Name 006TaxExeption.jpg  Date:01/15/2019
Name 007 2018 Code Inspection Report.jpg  Date:01/15/2019
Name 008 1 Code Occupancy R3 .jpg  Date:01/15/2019
Name 009 2 Code Occupancy R3.jpg  Date:01/15/2019
Name 010 1 State FMarshall Letter.jpg  Date:01/15/2019
Name 011 2 State FMarshall Letter.jpg  Date:01/15/2019
Name 012 3 State FMarshall Letter.jpg  Date:01/15/2019
Name GRACE Pictures.jpg  Date:01/15/2019
Name Building Inspection 1605_001.pdf  Date:01/15/2019
Name Division of Fire and Building Safety.pdf  Date:01/15/2019
Giving Recovery A Chance Everyday (GRACE)  6941 SR 64 
Marengo 47140  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
CRAWFORD 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
12-4-11(b)
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19086 WITHDRAWN BY PROPONENT 02/04/2019. 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
12-4-11(b)
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
19089 (Online)
Application Date:01/15/2019
Name Cardinal Services_Floor Plan.pdf  Date:01/21/2019
Cardinal Services  500 S Buffalo St 
Warsaw 46580  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
KOSCIUSKO 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 1015.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19089 WITHDRAWN BY PROPONENT 02/27/19. The code requires adult daycare classrooms with a calculated occupant load exceeding 10 to have at least two exits out of each classrooms. The request is to allow the classrooms to have one exit. Proponent states the maximum occupant load in the classrooms will be limited to 10. Common path of travel from within the classrooms will be less than 50 feet; code permits 75 feet. Exit access travel distance will be less than 150 feet; code permits 200 feet. Building will be fully sprinklered as required. Grocery store is being converted into adult day services, offices, and warehouse for light manufacturing and skills training.  
19099
Application Date:01/18/2019
Name EVSC - Construction Set V2.pdf  Date:01/18/2019
Name August Order - SFM McCutchanville Re-inspection 8-30-18.pdf  Date:01/18/2019
Name North Elem School - Nature of non-compliance.pdf  Date:01/18/2019
Name North Elem School - Not adverse to HSW.pdf  Date:01/18/2019
Name North Elem School - Result in undue hardship.pdf  Date:01/18/2019
New Northside Elementary School  10701 Petersburg Road 
Evansville 47725  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO Notified!
LBO Notified!
VANDERBURGH 
19103 (Online)
Application Date:01/23/2019
Name H-MRL Code Deviations.pdf  Date:01/23/2019
Hancock Regional Health Phase 1 Clinic  200N and N 600W 
GREENFIELD 46104  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
HANCOCK 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
3.26.8 ASME A17.1 2007
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19103 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19104 (Online)
Application Date:01/23/2019
Name H-MRL Code Deviations.pdf  Date:01/23/2019
Glasswater Creek Plainfield  10480 Glasswater Lane 
Plainfield 46168  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19104 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19105 (Online)
Application Date:01/23/2019
Name H-MRL Code Deviations.pdf  Date:01/23/2019
Jefferson High School Natatorium Renovations  1801 South 18th St 
LAFAYETTE 47905  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
TIPPECANOE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19105 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19106 (Online)
Application Date:01/23/2019
Name H-MRL Code Deviations.pdf  Date:01/23/2019
Ivy Tech Kokomo Campus Building 2  1901 E Morgan St 
KOKOMO 46903  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
HOWARD 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19106 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19107 (Online)
Application Date:01/23/2019
Name H-MRL Code Deviations.pdf  Date:01/23/2019
Sala Motor Freight Line LLC  4940 & 4960 Decatur Blvd 
INDIANAPOLIS 00000  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.36.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19107 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19109 (Online)
Application Date:01/24/2019
Name H-MRL Code Deviations.pdf  Date:01/24/2019
The Notch at Nora  8502 Westfield Blvd. 
Indianapolis 46240  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19109 (a) MRL Technology. 
Code Name:ASME A17.1 2007 [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3,19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology. 
19111 (Online)
Application Date:01/25/2019
Talley Eye Institute  6149 E. Columbia St 
Evansville 47715  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
VANDERBURGH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19111 (a) MRL Technology. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) MRL Technology.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(d) MRL Technology 
19112 (Online)
Application Date:01/25/2019
Name title page.PDF  Date:01/25/2019
Name S-1 Tippe Site.PDF  Date:01/25/2019
Name A-1.PDF  Date:01/25/2019
Name A-2.PDF  Date:01/25/2019
Name A-3.PDF  Date:01/25/2019
Name A-4.PDF  Date:01/25/2019
Name A-5.PDF  Date:01/25/2019
Name A-6.PDF  Date:01/25/2019
Name A-7.PDF  Date:01/25/2019
Name A-8.PDF  Date:01/25/2019
Name A-9.PDF  Date:01/25/2019
Name A-10.PDF  Date:01/25/2019
Name A-11.PDF  Date:01/25/2019
Name A-12.PDF  Date:01/25/2019
8 Unit Senior Patio Villas  101 102 Delmar Ct 
WARSAW 00000  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
KOSCIUSKO 
Code Name: [view code Details]
Specific Section:
2014 IBC 903.3.1.2 903.3.1.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19112 The code requires at least an NFPA 13R sprinkler system to be provided in all buildings with a Group R fire area. The request is to allow an NFPA 13D system to be used in lieu of an NFPA 13R system. These are 1-story senior rental units. Units are separated with 1-hour wall as required, along with the garage.  
19114 (Online)
Application Date:01/30/2019
Name Bldg A,H Bound.pdf  Date:01/30/2019
Name Bldg B,D Bound.pdf  Date:01/30/2019
Name Bldg C - Bound.pdf  Date:01/30/2019
Name Bldg E - Bound.pdf  Date:01/30/2019
Name Bldg F - Bound.pdf  Date:01/30/2019
Name Bldg G - Bound.pdf  Date:01/30/2019
Name Bldg J,S - Bound-REV1.pdf  Date:01/30/2019
Name Bldg K,R - Bound-REV1.pdf  Date:01/30/2019
Name Bldg L,M,T - Bound-REV1.pdf  Date:01/30/2019
Name Bldg N - Bound.pdf  Date:01/30/2019
Name Bldg P - Bound.pdf  Date:01/30/2019
Name Bldg Q - Bound-REV1.pdf  Date:01/30/2019
Name Warsaw Site Plan.pdf  Date:01/30/2019
Redwood at Warsaw  Prosperity Drive 
Warsaw 46582  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
KOSCIUSKO 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 903.3.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19114 The code requires at least an NFPA 13R sprinkler system to be provided in all buildings with a Group R fire area. The request is to allow an NFPA 13D system to be used in lieu of an NFPA 13R system. These are 1-story units. Units are separated with 1-hour wall as required. Proponent states, the water utilities are sized for 1 and 2-family dwellings. This is phase 1 of a new project. Which buildings?  
19117 (Online)
Application Date:02/01/2019
Name IU Bloomington plans (1 of 2).pdf  Date:03/25/2019
Name IU Bloomington plans (2 of 2).pdf  Date:03/25/2019
IUH Bloomington Academic Health Center  SR46 and 14th Street 
Bloomington   [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MONROE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC Section 1018.4
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19117 PLANS 
19120 (Online)
Application Date:02/04/2019
Name GARVIN LOFTS -- 107 N GARVIN STREET 08-30-2018 1040AM.pdf  Date:03/15/2019
Name MRL VARIANCE_001.pdf  Date:03/15/2019
Garvin Lofts  107 N.Garvin St 
Evansville 47711  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
VANDERBURGH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.7 2007 3.19.4.5
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19120 (a) MRL Technology.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 3.19.4.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) MRL Technology.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.19.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) MRL Technology 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(d) MRL Technology. 
19133 (Online)
Application Date:02/11/2019
Name 180403 Goshen IN Variance Drawings.pdf  Date:02/11/2019
Name Variance Drawings.pdf  Date:02/11/2019
Dollar Tree Goshen IN  2323 Lincolnway E 
GOSHEN 46526  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ELKHART 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
903.2.11.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19133 The code requires a sprinkler system to be provided throughout all stories where the floor area exceeds 1,500 sq. ft. unless there are openings of at least 20 sq. ft. in each 50 linear feet or fraction thereof located in exterior walls. If the required openings are provided on only one side and the opposite wall of the story is more than 75 feet from each openings, a sprinkler system is required, or the required openings are to be located on at least 2-sides of the story. The opposite wall is located approximately 81 feet 4 inches from openings. Proponent states plans were released and building construction is complete and it would be a hardship if more openings have to be installed. Proponent contends sprinkler system is not required. Building will have fire alarm system.  
19138 (Online)
Application Date:02/12/2019
Green Acres Technology Park Office Building  10900 USA Parkway 
Fishers   [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 712.1
Staff Recommendation:I (explanation key at the top of the table)

Staff Comments:19138 No plans 
19146 (Online)
Application Date:02/12/2019
Name Bonteville Wood Products A1.pdf  Date:02/12/2019
Name Bonteville Wood Products A2 (11-19-18).pdf  Date:02/12/2019
Bonteville Wood Products  9220 W 100 S 
Shipshewana 46565  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
LAGRANGE 
Code Name: [view code Details]
Specific Section:
2014 IBC 903.2.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19146 The code requires a sprinkler system to be installed throughout all Group F-1 fire areas that contain woodworking operations in excess of 2,500 sq. ft. in area which produces finely divided combustible waste or use finely divided combustible materials. The request is to allow an NFPA 664 Dust Collection System to be used (2012) in lieu of the sprinkler system. Proponent states the dust collection system will remove the dust immediately away from the machines and from the building operations. Existing building and new addition is 9,008 sq. ft. There is no city water supply.  
19147 (Online)
Application Date:02/12/2019
Name A1.pdf  Date:02/12/2019
Name A2.pdf  Date:02/12/2019
Hoosier Pedestals  6545 S SR 5 
Topeka 46571  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
LAGRANGE 
Code Name: [view code Details]
Specific Section:
2014 IBC 903.2.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19147 The code requires a sprinkler system to be installed throughout all Group F-1 fire areas that contain woodworking operations in excess of 2,500 sq. ft. in area which produces finely divided combustible waste or use finely divided combustible materials. The request is to allow an NFPA 664 Dust Collection System to be used (2012) in lieu of the sprinkler system. Proponent states the dust collection system will remove the dust immediately away from the machines and from the building operations. Warehouse/mfg area is 9,600 sq. ft. There is no city water supply.  
19148 (Online)
Application Date:02/12/2019
Name A1.pdf  Date:02/12/2019
Name A2.pdf  Date:02/12/2019
Double L Woodworking  12478 CR 34 
Goshen 46528  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
ELKHART 
Code Name: [view code Details]
Specific Section:
2014 IBC 903.2.4.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19148 The code requires a sprinkler system to be installed throughout all Group F-1 fire areas that contain woodworking operations in excess of 2,500 sq. ft. in area which produces finely divided combustible waste or use finely divided combustible materials. The request is to allow an NFPA 664 Dust Collection System to be used (2012) in lieu of the sprinkler system. Proponent states the dust collection system will remove the dust immediately away from the machines and from the building operations. Warehouse/mfg. area is 11,520 sq. ft. There is no city water supply.  
19151 (Online)
Application Date:02/12/2019
Name 4483 Clif Bar Temp Plan.pdf  Date:02/12/2019
Clif Bar Temporary Facilities  7575 Georgetown Rd 
INDIANAPOLIS 46268  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 507.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19151 (a) The code permits 1-story Group E occupancy (school) to be unlimited in area where the building is fully sprinklered and is surrounded with public ways or yards not less than 60 feet. The request is to allow a new mobile structure to be approximately 1-inch away from the existing building, placing the existing building in non-compliance for an unlimited area building. Proponent states the condition will last until January 3, 2020. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 903.3.1.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) Mobile structure will not be sprinklered. Condition will last until January 3, 2020.  
Code Name:2009 Indiana Electrical Code (675 IAC 17-1.8) [view code Details]
Specific Section:
Article 230.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(c) The code prohibits service conductors supplying a building or other structure from passing through the interior of another building or other structure. The request is to allow the temporary mobile structure to receive its power from the adjacent building. The mobile structure will have disconnect switch accessible to personnel and local fire department. Condition will last until January 3, 2020. 
19153 (Online)
Application Date:02/12/2019
Name VARIANCE Main St - Jeremiah full building.pdf  Date:02/12/2019
310 On Main ¿ Jeremiah Buildout  310 North Main Street 
Auburn 00000  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
DEKALB 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 2902.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19153 The code requires public toilet facilities to be provided in structures and tenant spaces utilized as restaurants. The request is to allow a 4,982 sq. ft. restaurant, located inside of a YMCA building, to have fully accessible restrooms located across the corridor, approximately 8 feet away in lieu of within the restaurant space. Proponent states the restrooms will be available at all times the restaurant is open.  
19182 (Online)
Application Date:02/13/2019
Name 17067_2019-02-12_TippecanoeColiseum_code.pdf  Date:02/13/2019
Tippecanoe County Fairground Improvements Project Phases 2,3  1406 Teal Road 
Lafayette 47905  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
TIPPECANOE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
602.1 and Table 601, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19182 The code permits structural members of building or structures to be non-rated where every part of the roof construction is 20 feet or more above any floor immediately below. A portion of the non-rated roof structure is 14 feet above the floor below and will have exposed steel columns. The request is to allow the steel columns to be non-rated. The areas where the roof is less than 20 feet above the floor will have its sprinkler density and spacing increased from Ordinary Hazard Group 1 to Ordinary Hazard Group 2. Exposed steel columns will have additional sprinkler heads located at columns. Building is fully sprinklered with NFPA 13 system as required.  
19183 (Online)
Application Date:02/14/2019
Name Pics.docx  Date:03/18/2019
Name Construction.docx  Date:03/18/2019
Temeray Store/Classroom   5233S 5e 
Wabash 46992  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
WABASH 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
675 Iac 12-6-3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19183 The code prohibits any construction from being done on a Class I structure until a design release has been issued by Plan Review unless the building or structure is exempted from the design release requirement. The request is to allow a 16 feet x 40 feet shed to be used as a classroom and teacher's space to teach students how to grow plants in the greenhouses without having to file the project with Plan Review.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:

Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
19184 (Online)
Application Date:02/15/2019
Name Fan Fire Inspection Report.pdf  Date:02/15/2019
Install 17 new HVLS Fans  5349 W 76th Street 
Indianapolis 46268  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:NFPA 13 - 2010 [view code Details]
Specific Section:
8.6.5.2.1.10
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19184 The code permits sprinklers to be placed without regard to the blades of ceiling fans less than 60 inches in diameter as long as the plan view of the fan is at least 50 percent open. The request is to allow warehouse ceiling fans to be over 60 inches. Violation was written with the stipulation that a shunt trip had been installed to the fire alarm to shut down fans if the fire alarm system is activated.  
19185 (Online)
Application Date:02/18/2019
Name IDI Fabrication.jpeg  Date:02/18/2019
Name SITE PLAN NOTES.pdf  Date:02/18/2019
Name NFPA 30 Chapter 13.pdf  Date:02/18/2019
Outbuilding Storage  14444 Herriman Blvd 
Noblesville 46060  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
903.2.5, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19185 The code requires an automatic sprinkler system to be provided in Group H (high-hazard) occupancies. The request is to allow a 410 sq. ft. building used for the storage of drums of Class 1-C flammable liquids to not be sprinklered. Proponent states the building will normally be unoccupied and is located approximately 100 feet from any other building on the same site. The storage will be limited to a maximum of 20, 55 gallon drums of Class 1-C liquid.  
19186 (Online)
Application Date:02/19/2019
Name Hampton Layouts.pdf  Date:02/19/2019
Name Hampton PD1.pdf  Date:02/19/2019
Name Hampton PD2.pdf  Date:02/19/2019
HAMPTON INN   10496 COMMERCE DRIVE  
FRANKLIN  46131  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
JOHNSON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ANSI ASME A 17.1-2007, 2.20.1,
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19186 Schindler Elevator will utilize 6mm steel wire governor rope instead of the required minimum diameter of 9.5mm. 
19187 (Online)
Application Date:02/19/2019
Name Wabash Layouts.pdf  Date:02/19/2019
Name Wabash PD.pdf  Date:02/19/2019
WABASH VALLEY POWER  6702 INTECH BLVD 
INDIANAPOLIS  46278  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ANSI ASME A 17.1-2007, 2.20.1,
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19187 Schindler Elevator will utilize 6mm steel wire governor rope instead of the required minimum diameter of 9.5mm. 
19188 (Online)
Application Date:02/19/2019
Name University Layouts.pdf  Date:02/19/2019
Name University PD.pdf  Date:02/19/2019
UNIVERSITY PARK STUDENT HOUSING  2110 S LAFOUNTAIN ST 
KOKOMO 46902  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HOWARD 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ANSI ASME A 17.1-2007, 2.20.1,
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19188 Schindler Elevator will utilize 6mm steel wire governor rope instead of the required minimum diameter of 9.5mm. 
19190 (Online)
Application Date:02/21/2019
North Decatur Elementary School Roof Replacement  3300 N SR 3 
Greensburg 47240  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO Notified!
LBO Notified!
DECATUR 
Code Name:2014 IBC [view code Details]
Specific Section:
Ch. 15, Sec. 1510, Par 1510.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19190 The code prohibits new roof covering from being installed on existing roofs where there are two or more applications of any type of roof covering. All existing layers of roof covering must be removed down to the roof deck before any new roof covering can be installed. The request is to allow only one layer to be removed. Proponent states An IR scan will be done to locate all wet insulation. All wet components will be removed. Deck at insulation replacement areas will be examined for deterioration and replaced where needed. Per the proponent, insurance company will not cover the cost to remove all layers and replacement of all insulation.  
19191 (Online)
Application Date:02/25/2019
The Mark at Fishers Disctrict  1242 Fishers Dr 
Fishers 46037  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
HAMILTON 
Code Name:2012 Indiana Plumbing Cod, (675 IAC 16-1.4) [view code Details]
Specific Section:
305.8
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19191 In concealed locations, piping installed through holes or notches in studs, joists, rafters, or similar members less than 1.5 inches from the nearest edge of the member is to be protected by shield plates having a minimum thickness of 0.062-inch-thick steel. The request is to allow nail guards 1"- ½" x 3" and 18GA thick to be used.  
19192 (Online)
Application Date:02/25/2019
Name 2019 St Lukes.pdf  Date:02/25/2019
St Lukes UMC Tent Extension  100 W 86th Street 
Indianapolis 46260  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: [view code Details]
Specific Section:
2014 IFC 3103.5
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19192 The code allows temporary tent structures to be in place for no more than 30 days. The request is to allow the church to continually use the tent for community events through the summer months; approx. 12-15 weeks. What are the dates? 
19193 (Online)
Application Date:02/26/2019
Name A127 - FLOOR PLAN - SEVENTH FLOOR.pdf  Date:02/26/2019
Eskenazi Mental Health Recovery Expansion  720 Eskenazi Ave 
INDIANAPOLIS 46202  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
IBC 2014-1107.5.3.1 Accessible
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19193 The code requires at least 10%, but not less than one, of the sleeping units to be accessible units. The request is to allow none of the patient rooms (sleeping units) to be fully accessible. Accessible toilets/showers do not have vertical grab bars or shower seats. Proponent states the units are within a psychiatric unit and both the vertical grab bar and shower seat pose hanging risks. All patients are typically ambulatory. Staff will assist patients when required. Portable benches and wand hoses are available for patients use. Per the proponent, the expansion is equipped the same as the original units.  
19194 (Online)
Application Date:02/28/2019
Name 649278-LAYOUT.pdf  Date:02/28/2019
Loretto Convent Renovation  100 Lourdes Hall 
Notre Dame 46151  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ST JOSEPH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.20.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19194 (a) Steel coated belts will be used as the suspension means.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.18.5.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(b) Gen2 elevator will utilize 6.3 mm governor rope instead of the required minimum diameter of 9.5mm.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 yr 2.22.1.1
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:(c) Gen2 elevator will use ACLA buffers in place of spring buffers.  
19196 (Online)
Application Date:02/28/2019
Name Image (2).jpg  Date:02/27/2019
Name Image (2).jpg  Date:02/28/2019
Name Image-19 (1).jpg  Date:02/28/2019
Villas of Saxony  13233 E. 131st St. 
Fishers   [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name:2005 Indiana Residential Code (675 IAC 14-4.3) [view code Details]
Specific Section:
R311.5.6.2
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:WITHDRAWN BY PROPONENT 03/04/19. 
19197 (Online)
Application Date:03/01/2019
Name 2018 Fire Marshall Inspection Report.pdf  Date:03/01/2019
Buskirk Chumley Theater  114 E Kirkwood Ave 
Bloomington 47404  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MONROE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 Indiana Fire Code 901.4
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19197 The code requires fire protection system to be maintained in accordance with the original installation. Violation was written. Missing nine or more sprinkler head covers in the main theater, escutcheon ring in the concessions. Proponent states the covers are part of the listed assemble, but is primarily for decorative purposes and will not affect the operation of the sprinkler. They are located in the high ceiling of the main auditorium above the fixed seating. Per the proponent, to rectify the problem, it would cost over $120,000.00. 
19198 (Online)
Application Date:03/01/2019
Name VARIANCE PLANS.pdf  Date:03/01/2019
Name VARIANCE byers barn structural evaluation report.pdf  Date:03/01/2019
Name VARIANCE A-2 Byers Barn Summary Score Sheet # 2533-.pdf  Date:03/01/2019
Name VARIANCE A-2 Byers Barn Score Sheet # 2533-.pdf  Date:03/01/2019
Janet Byers ¿ Wedding Barn  2595 S 625 W 
Topeka 46571  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
LAGRANGE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 3401.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19198 A Chapter 34 Evaluation will be used to convert a barn into a building used as a 2-story 5,686 sq. ft. wedding event space Type V-B construction. Chapter 34 is not permitted to be utilized for a conversion of a non-Class 1 structure building into an A occupancy. Shunt trip will be provided. Permanent restroom facilities will be provided onsite in adjacent building. Two new exits will be provided, one exit at grade the other by a new enclosed stair exiting directly to the exterior. Will the restroom fixtures in the adjacent building be enough to accommodate the occupant load in this building? What is the occupant load? 
19199 (Online)
Application Date:03/04/2019
Name Milltown Fire Dept.pdf  Date:03/21/2019
Removal of Hose Stations at Crawford County High School  1130 S St Rd 66 
Marengo 47140  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
CRAWFORD 
Code Name:2014 IFC [view code Details]
Specific Section:
901.6
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19199 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the fire hoses to be removed from the gym. Fire official sent letter stating the fire department will not be using the fire hoses that are currently in the gym due to them being outdated and they need to be removed.  
19200 (Online)
Application Date:03/05/2019
Brooke Point Inn  4906 E 1200 N 
Syracuse 46567  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
KOSCIUSKO 
Code Name:2014 IBC [view code Details]
Specific Section:
903.2.8
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19200 PLANS 
19201 (Online)
Application Date:03/08/2019
Name 090718 17523 C G Bid Drawings.pdf  Date:03/07/2019
Name Stamped Parkreation Structural Calcs Centennial & Groff.pdf  Date:03/07/2019
Name Stamped Parkreation Drawing Centennial & Groff.pdf  Date:03/07/2019
Centennial and Groff Splash Pad  2320 N Centennial Ave 
INDIANAPOLIS 00000  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:2008 Indiana Building Code (675 IAC 13-2.5) [view code Details]
Specific Section:
Unknown
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments: 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
Section 1608 2014 Indiana B.C.
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19201 Snow load calculations will not be done on fabric canopy. Proponent states the canopy will be removed from the shade structure before winter and snow accumulation. This will be done as part of the shutdown and maintenance of the park.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
675 IAC 13-2.5-17 Chapter 16
Staff Recommendation:VOID (explanation key at the top of the table)

Staff Comments:VOID 
19202 (Online)
Application Date:03/08/2019
Name 2019_03_19 Variance Letter 2018021.pdf  Date:03/08/2019
Name 2019_03_06 DPW to WA Email 2018021.pdf  Date:03/08/2019
Name STR19-00843 Notice of 1st Review.pdf  Date:03/08/2019
Name Parkreation stamped calculations Windsor Village.pdf  Date:03/08/2019
Name stamped parkreation drwg Windsor Village.pdf  Date:03/08/2019
Name 2018_12_06 Windsor Village Splash Pad DWGS.pdf  Date:03/08/2019
Windsor Village Splash Pad  6510 E. 25th St 
Indianapolis 46219  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
IBC 2012, Chapter 16, 1607.12
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19202 Snow load calculations will not be done on fabric roof. Proponent states the fabric roof, seasonal shade structure will be removed by City of Indianapolis, Department of Public Works personnel if snow is expected.  
19203 (Online)
Application Date:03/09/2019
Name Lake Central HS Band Tower Drawings.pdf  Date:03/09/2019
Lake Central High School Band Tower  8400 Wicker Avenue 
St John 46373  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
LAKE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1009, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19203 The code requires stairs to have a maximum riser height of 7 inches and 4 inches minimum. Handrails are to be continuous, without interruption by newel post or other obstructions and extend between flights. The request is to allow the 23 feet high band observation tower to have stairs that will have a maximum riser height of 9 ¼-inches and 8-inches minimum and handrails that are not configured as required for conventional stairs. Proponent states the observation tower will be used by the band director to observe and direct the movements of the band. Structure is not open to the public or students. Per the proponent, the structure is designed by OSHA.  
19204 (Online)
Application Date:03/09/2019
Name FFD 93_A120 - ARCHITECTURAL PLAN.pdf  Date:03/09/2019
Fishers Fire Station #93  10501 Allisonville Road 
Fishers 46038  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1103.1, 2014 IBC
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19204 The code requires buildings, structures, facilities, elements and spaces, to be accessible to person with physical disabilities. The request is to allow the 1-story fire station to have its area used by firefighting personnel to not be accessible. Accessible restrooms will be provided for use by any visitors.  
19205 (Online)
Application Date:03/09/2019
Name FFD91 - Architectural Plans(1).pdf  Date:03/09/2019
Fishers Fire Station #91  2 Municipal Drive 
Fishers 46038  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1103.1, 2014 IBC
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19205 The code requires buildings, structures, facilities, elements and spaces, to be accessible to person with physical disabilities. The request is to allow the 2-story fire station to have its area used by firefighting personnel to not be accessible. All employment positions available to the physically disabled and areas accessed by the general public will be provided with fully accessible facilities. 
19206 (Online)
Application Date:03/09/2019
Name CityWay Unit Stair Variance Exhibit.pdf  Date:03/09/2019
CityWay Phase II Building A  312 Louisiana St 
INDIANAPOLIS 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1009.10, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19206 The code prohibits flight of stairs from having a vertical rise of more than 12 feet between floor levels or landings. The request is to allow the units on the 4th floor to have stairs that will have a vertical rise between landings of 12 feet, 1.5 inches. Proponent states the individual stairs (3 total) are within individual dwelling units and will be used to access the unit's rooftop terrace. Issues with the roof's waterproofing resulted in the roof decks having to be raised a few inches from the original design and one riser was added to each of the stairs.  
19207 (Online)
Application Date:03/09/2019
Name CityWay Unit Stair Variance Exhibit.pdf  Date:03/09/2019
CityWay II Building B1   231 Virginia Ave 
INDIANAPOLIS 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1009.10, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19207 The code prohibits flight of stairs from having a vertical rise of more than 12 feet between floor levels or landings. The request is to allow the units on the 4th floor to have stairs that will have a vertical rise between landings of 12 feet, 1.5 inches. Proponent states the individual stairs (13 total) are within individual dwelling units and will be used to access the unit's rooftop terrace. Issues with the roof's waterproofing resulted in the roof decks having to be raised a few inches from the original design and one riser was added to each of the stairs.  
19208 (Online)
Application Date:03/09/2019
Name CityWay Unit Stair Variance Exhibit.pdf  Date:03/09/2019
CityWay Phase II Building B2  322 Louisiana St 
INDIANAPOLIS 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1009.10, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19208 The code prohibits flight of stairs from having a vertical rise of more than 12 feet between floor levels or landings. The request is to allow the units on the 4th floor to have stairs that will have a vertical rise between landings of 12 feet, 1.5 inches. Proponent states the individual stairs (2 total) are within individual dwelling units and will be used to access the unit's rooftop terrace. Issues with the roof's waterproofing resulted in the roof decks having to be raised a few inches from the original design and one riser was added to each of the stairs.  
19209 (Online)
Application Date:03/10/2019
Name 171501_CQVarianceApplication_602-AllSigs.pdf  Date:03/10/2019
Name 171501_CQVarianceApplication_903-AllSigs.pdf  Date:03/10/2019
Name 171501_CQVariances_LFO_LetterOfNoObjection.pdf  Date:03/10/2019
Name 171501_C101.pdf  Date:03/10/2019
Name 171501_G101.pdf  Date:03/10/2019
Name 171501_G102.pdf  Date:03/10/2019
Name 171501_G103.pdf  Date:03/10/2019
Name 171501_FP101.pdf  Date:03/10/2019
Name NationalRegisterCoverPage.pdf  Date:03/10/2019
Name NationalRegisterDatabaseInfo.pdf  Date:03/10/2019
Name ExistingBasement_Picture1_beforeConstruction.jpg  Date:03/10/2019
Name ExistingBasement-Picture3_duringConstruction.jpg  Date:03/10/2019
Name ExistingBasement-Picture2_duringConstruction.jpg  Date:03/10/2019
Campaign Quarters Apartments  131 W 2nd St 
RUSHVILLE 46173  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
RUSH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 903.2.8
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19209 (a) The code requires an automatic sprinkler system to be provided throughout all buildings with a Group R fire area. The request is to allow the sprinkler system to be omitted until no later than October 1, 2019. Proponent states however, the sprinkler system will be energized by early September 2019. The existing 3-story hotel and apartment building is being renovated and expanded into 19 senior housing apartments. The renovated apartments on the first floor of the existing building will be occupied before the sprinkler system is installed. Renovation only of the existing building would not require a sprinkler system. The new addition triggers the sprinkler system. Building must be leased and occupied by May 31st in order to receive funding for the historic building.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Section 602.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) The code requires buildings or structures of Type V-A construction to have its floor-ceiling assembly to be of 1-hour construction. The request is to allow the existing low headroom basement, used for mechanical / utilities only, to not be separated from the floor above with a 1-hour floor-ceiling assembly. Proponent states the basement will not be occupied, except for maintenance of utilities. New piping systems reduced the headroom in some of the areas to 3 feet or less. Basement will be sprinklered with NFPA 13 system, currently basement is not sprinklered.  
19210 (Online)
Application Date:03/11/2019
Name Brownsburg Cardinal and Delaware Trail ES Base Plan.pdf  Date:03/11/2019
Brownsburg Cardinal Elementary School  3590 Hornaday Road 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19210 The code requires all buildings and structures and any part of the fire or explosion system to be maintained. The request is to allow the smoke detection system and fire alarm pull stations to be removed due to them not being required by today's current rules of the Commission. Building is fully sprinklered as required.  
19211 (Online)
Application Date:03/11/2019
Eagle Elementary School  555 Sycamore Street 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19211 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19212 (Online)
Application Date:03/11/2019
Reagan Elementary School  4845 Bulldog Way 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19212 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19213 (Online)
Application Date:03/11/2019
Name Signed Variance Application Triple LLL Truck.pdf  Date:03/11/2019
Name Triple L letter Andrews Volunteer Fire Department.pdf  Date:03/11/2019
Name Triple LLL Truck Repair Inc Department of Community Development.pdf  Date:03/11/2019
Name Signed-Water Supply-LLL Truck Town of Andrews.pdf  Date:03/11/2019
Name Triple LLL Truck Repair Variance Set.pdf  Date:03/11/2019
Triple LLL Truck Repair, Inc.  8254 W 300 N 
Andrews 46702  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HUNTINGTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
903.2.9.1 Repair Garages
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19213 The code requires a sprinkler system to be provided in 1-story buildings with a fire area containing a repair garage exceeding 12,000 sq. ft. The request is to allow the sprinkler system to be omitted in the 13,357 sq. ft. building. Automatic fire alarm system, with smoke and heat detectors, manual pull stations, horns and strobes, that will automatically notify the local fire department, will be installed. Proponent states nearest water supply is 5,000 feet and is a 4¿ main that doesn't haven't sufficient pressure. Local fire and building officials do not oppose the variance. See attached letter.  
19214 (Online)
Application Date:03/11/2019
Name OBannon Soccer Park - Variance Documentation.pdf  Date:03/11/2019
Name OBannon Soccer Park - Variance Documentation.pdf  Date:03/11/2019
Frank & Judy O'Bannon Soccer Park  1001 E. 16th Street 
Indianapolis 46202  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
675 IAC 20-5-24 (f)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19214 (a) The code requires all water attractions to be enclosed in an at least 6 feet fence, wall, or other enclosure in order to control the movement of bathers and to discourage the entrance of unwanted persons. The request is to allow the 6 feet fence or barrier requirement to be omitted. Proponent states the splash pad is zero-depth and drains directly to the sewer.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
675 IAC 20-5-25, Table 25-1
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:(b) The code requires a rinse off shower to be provided for splash pads. The request is to allow the rinse-off shower to be omitted. Proponent states the splash pad does not have a recirculating system. Therefore, does not use chemically-treated water.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
675 IAC 20-5 Sec. 14 & 15
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:(c) The code requires filtration and recirculation systems to be provided through all parts of the water attraction. The request is to not install the systems since the water will discharge directly to a sewer and not re-circulated. Similar variances have been granted in the past.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
675 IAC 20-5-24(e)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:(d) The code requires a telephone located within three hundred (300) feet of the pool with posted names and emergency numbers for the nearest police, fire, and emergency responders or 9-1-1, or both and one twenty four unit first aid kit, within 300 feet of each water attraction. The request is to not install telephones since majority of the public will have cell phones and there will be no supervisors for the splash pad to issue first aid.  
19215 (Online)
Application Date:03/11/2019
Lincoln Elementary School  4807 Bulldog Way 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19215 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19216 (Online)
Application Date:03/11/2019
White Lick Elementary School  1400 South Odell Street 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19216 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19217 (Online)
Application Date:03/11/2019
Brownsburg West Middle School  1555 South Odell Street 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19217 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19218 (Online)
Application Date:03/11/2019
Brownsburg East Middle School  1250 East Airport Road 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19218 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19219 (Online)
Application Date:03/11/2019
Brownsburg High School  1000 South Odell Street 
Brownsburg  46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19219 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19220 (Online)
Application Date:03/11/2019
Harris Elementary School  725 South Green Street 
Indianapolis 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19220 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19221 (Online)
Application Date:03/11/2019
Name B97_12_09.pdf  Date:03/14/2019
Brown Elementary School  340 South Stadium Drive 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19221 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19222 (Online)
Application Date:03/11/2019
310 Stadium Drive  310 Stadium Drive 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
12-4-9 (d)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19222 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the smoke detection systems to be removed, along with the fire alarm pull stations. Proponent states they are not required by current code. Building is fully sprinklered with NFPA 13 system as required by code.  
19223 (Online)
Application Date:03/11/2019
Name White River State Park Phase 2 Site Plan.pdf  Date:03/11/2019
Name Variance 05-09-19(s).pdf  Date:03/14/2019
White River State Park Concert Venue Phase Two  801 West Washington Street 
Indianapolis 46204  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
Table 2902.1, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19223 (a) The code requires drinking fountains to be based on 1 per 1,000 occupants. Per the proponent, there are approximately 3,500 persons that will be outdoors in fixed seats. Four new drinking fountains are required at the new North Restrooms location. The request is to allow the new drinking fountains to be omitted. Proponent states there is an existing drinking fountain at the South Restroom building. Concession stand will provide beverages.  
Code Name:2010 Indiana Energy Conservation Code (675 IAC 19-4) [view code Details]
Specific Section:
4.1.1.1
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:(b) The seasonal restroom and artist amenity buildings will not be designed to comply with the Energy Code. Based upon the provision of intermittent seasonal conditioning of the areas, full compliance with the Energy Code is required. Proponent states small conditioning units will be used to provide minimal heat intermittently during seasonal periods as needed when the buildings are occupied.  
19224 (Online)
Application Date:03/12/2019
Name datasheet-c78-736497.pdf  Date:03/12/2019
Name Elevator Locations.pdf  Date:03/23/2019
Name Deaconess Shaft Mount.jpg  Date:03/23/2019
Name Deaconess Entry Point.jpg  Date:03/23/2019
Deaconess Gateway Complex WAP for Elevators  4011-4199 Gateway Blvd 
Newburgh 47630  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
WARRICK 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
In Elev Code 2.8.1 Misc Equipm
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19224 
19225 (Online)
Application Date:03/12/2019
Name Gathering Acres-Revised Drawings.pdf  Date:03/12/2019
Name LAFAYETTE EVENT CENTER 2-22-19 Brown Sprinkler.pdf  Date:03/12/2019
Name Gathering Acres-Agricultural Exhibit Hall.pdf  Date:03/12/2019
AGRICULTURAL EXHIBIT HALL  5074 E 550 S 
LAFAYETTE 47905  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
TIPPECANOE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Table 1004.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19225 (a) The code requires the number of occupants to be computed based at the rate of one occupant per unit of area. Proponent states based on 15 sq. ft. (tables and chairs), the calculated occupant load for the area will be 464 persons (per code summary sheet)requiring an automatic sprinkler system. Proponent is requesting to have a self-imposed occupant load of a maximum of 297 persons. Five exits will be provided instead of two exits.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 903.2.1.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) The code requires a sprinkler system to be provided in Group A-2 occupancy where the fire area has an occupant load of 100 or more. The request is to allow the sprinkler system to be omitted. Per the proponent, the calculated occupant load is 464 persons(per code summary sheet). Building is 7,812 sq. ft. A self-imposed occupant load a maximum of 297 will be posted. Monitored fire alarm with full smoke and heat detection, horn/strobes and pull stations will be installed. Pond is on the property. Proponent states nearest fire hydrant is over 2 miles away.  
19226 (Online)
Application Date:03/12/2019
Name 130 Washington-CombinedFinal.pdf  Date:03/12/2019
130 East Washington Street Renovation  130 E Washington St 
INDIANAPOLIS 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
Rule 4, Section 9(a)
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19226 The code requires all buildings and structures to be maintained in conformance with the applicable rules of the Commission, in effect when constructed, installed, or altered. The request is to allow the enclosed freight elevator lobby vestibule on each floor on the North end of the 12 story building to be eliminated. Building is fully sprinklered with NFPA 13 system as required.  
19227 (Online)
Application Date:03/12/2019
Name Grace CARE CENTER Addition Renovation Drawings.pdf  Date:03/12/2019
Name Grace Church 2004 Variance Application.pdf  Date:03/19/2019
Name Grace Church 2004 Variance Approval Letter.pdf  Date:03/19/2019
Grace Church Care Center  5504 E 146th St 
NOBLESVILLE 46062  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HAMILTON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 503.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19227 The code prohibits addition to buildings or structures plus the existing building or structure from exceeding the height, number of stories, and allowable area based on the construction type. The request is to allow new 7,520 sq. ft. exterior canopy additions to be added to the existing 2-story church (A-3 occupancy) and classify the building as unlimited in area. The new addition will put the existing building in non-compliance for Type II-B construction. A-3 occupancy is permitted to be unlimited in area if it's 1-story, fully sprinklered, has at least 60 feet of yard space around the building, and doesn't have a stage. Proponent states variance was granted in 2004 for existing building and additions to be classified as unlimited in area.  
19228 (Online)
Application Date:03/12/2019
Name Civic Center Parking Garage Variance Request for Stairs.pdf  Date:03/12/2019
Civic Center Parking Garage Expansion  100 E Washington Blvd. 
Fort Wayne 46802  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ANSI 117.1 404.2.3.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19228 (a) The code requires front approach doors to have an 18 inch pull clearance. The request is to allow the existing and new doors in the stairs to not have the required clearance. Existing width at stair landing is 6-8 inches. Proponent states the required clearances at doors to enter stairs and at ground level discharge from stair meet the requirements. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 1009.7
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) The code limits stair riser heights to a maximum of 7 inches. The request is to allow new stair riser heights to be a maximum of 7-3/16 inches. The riser heights will match the existing. Proponent states the new stair riser heights will be consistent between landings. The existing stairs have risers that vary in height between existing landings between 7 inches to 7 ¼ inches.  
19229 (Online)
Application Date:03/12/2019
Name Allure Dental CODE LIFE SAFETY SHEET.pdf  Date:03/12/2019
Allure Dental Addition  821 Twyckenham Blvd. 
Lafayette 47909  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
TIPPECANOE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Table 1018.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19229 The code requires corridor construction in Group B occupancy to be one hour fire rated when the occupant load it serves is 30 or greater and the building is not fully sprinklered. The request is to allow new corridor to be of non-rated construction. Proponent states the existing corridor is also non-rated. One story 4,020 sq. ft. addition is being added to existing 3,598 sq. ft. building. Building will be separated into two areas with smoke resistant wall to the ceiling. Both areas will have two separate exits. Rated corridors would not permit the check-in/out area to be open to the corridors.  
19230 (Online)
Application Date:03/12/2019
Name FH Beacon 1st Fl.pdf  Date:03/12/2019
Name FH Beacon 2nd Fl.pdf  Date:03/12/2019
Franciscan Beacon Hospital  900 1/2 I Street 
La Porte 46350  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
LAPORTE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC Section 407.4.3.4
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19230 (a) Other than sleeping rooms located within a care suite, the code permits a maximum of a 50 feet travel distance through two intervening rooms to an exit access door from the care suite. The request is to allow the travel distance to be approximately 100 feet through two or more intervening rooms to an exit access. The 2012 NFPA 101 - Life Safety Code permits a maximum 100 feet travel distance from non-sleeping patient care suites without limiting intervening rooms.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC Section 706
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19230 (b) The code requires a 2-hour fire wall when separating Group I occupancy of Type II-A occupancy from B occupancy of Type II-B construction (different construction types). The request is to allow a 2-hour fire barrier to be used to separate the existing building from the new addition, in lieu of a 2-hour structurally independent fire wall. Buildings are fully sprinklered as required. Similar variances have been granted in the past.  
19231 (Online)
Application Date:03/12/2019
Name UND Dillon Hall Floor Plans Proposed.pdf  Date:03/19/2019
Name UND Dillon Hall Demolition Floor Plans.pdf  Date:03/19/2019
Dillon Hall Renovation  University of Notre Dame 
Notre Dame 46556  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
ST JOSEPH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 716.5.9
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19231 (a) The code requires fire-doors to be either self-or automatic-closing. The request is to allow the dorm room doors to not be provided with closers. Identical variance has been granted in the past. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 3004.1
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:(b) The code requires hoistways of elevators and dumbwaiters in Group R-2 occupancy buildings that penetrates more than three stories to be provided with vents so that smoke and hot gases can be released to the outer air. The request is to allow the new elevator in the new dormitory building to not have hoistway venting. The 2015 International Building Code no longer requires venting of elevator hoistways. Similar variances have been granted in the past. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, Table 2902.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(c) The code requires plumbing fixtures to be provided based on the type of occupancy and occupant load. Based on 1 shower for every 8 occupants, 32 showers would be required. Proponent states in 2005 there were 27 showers provided for 346 residents. The building is being renovated. The renovation will reduce the occupant load to 253 with a total of 26 shower. The request is to allow 26 showers in lieu of 32 showers. Per the proponent, although not meeting code required showers, the renovation will increase the number of showers per resident. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 1018.6
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(d) The code permits foyers, lobbies, and reception rooms to be open to the corridor. The request is to permit the lounges and reading areas to be open to the corridor serving the dormitory, R-2 Occupancy.  
19233 (Online)
Application Date:03/12/2019
Name CICF 3rd Floor Plan.pdf  Date:03/12/2019
Central Indiana Community Foundation  615 North Alabama Street 
Indianapolis 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
1008.1.9, 2014 IBC
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19233 The code requires egress doors to be readily openable from the egress side without the use of a key or special knowledge or effort. The request is to allow card-reader devices to be used on the pair of doors leading from the elevator lobby into the tenant space on the 3rd floor. Without fire alarm actuation or loss of power, the doors will only open by card-reader activation. The 3rd floor is for employees and invited guests only, and not open to the general public. Building is fully sprinklered. Similar variances have been granted in the past.  
19234 (Online)
Application Date:03/12/2019
Name 4492 Fedex_Lower Level.pdf  Date:03/12/2019
Name 4492 Fedex_Upper Level.pdf  Date:03/12/2019
Name 4492 Fedex_SitePlan.pdf  Date:03/12/2019
FedEx Flights Ops & Crew Rest Quarters  Cargo Road & S. High School Road 
Indianapolis 46241  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC Table 2902.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19234 The code requires Group R-1 occupancies (hotels) to have 1 bathroom per sleeping unit. The request is to allow the facility to have common restroom and bathing facilities based on the anticipated need. Proponent states common bathrooms will be provided for the flight crews.  
19235 (Online)
Application Date:03/12/2019
AVC  6929 W 38th St 
Eagle Creek 46214  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:2009 Indiana Electrical Code (675 IAC 17-1.8) [view code Details]
Specific Section:
110.26(A)(1)
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19235 The code requires electric panel board to have minimum working clearances of 36 inches. The request is to allow the working clearance to be 34 inches from the existing wall to the panel board location. Proponent states this is an existing condition and never was a problem prior to any other previous inspections. Per the proponent, the distance between both outside existing wall and interior existing plumbing wall is 3'5". The existing electric panel on the outside wall created the 34 inches. 
19236 (Online)
Application Date:03/12/2019
Name Restoracy of Whitestown Life Safety Plans.pdf  Date:03/14/2019
Restoracy of Whitestown  5990 S 700 E 
WHITESTOWN 46075  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
BOONE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 407.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19236 The code permits waiting area and similar spaces to be open to the corridor. The request is to permit the living, dining room and kitchen to be open to the corridor in the nursing home, I-2 Occupancy. 
19237 (Online)
Application Date:03/12/2019
Name 4477 Plainfield Middle PLANS.PDF  Date:03/12/2019
Plainfield Community Middle School  709 Stafford Road 
Plainfield 46168  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC 1008.1.9.7
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19237 The code requires egress doors to be readily openable from the egress side without the use of a key or special knowledge or effort. The request is to allow delayed egress locks with 15 second delay to be used on the children special educational classroom doors. Sprinkler system is installed in the special educational classroom area.  
19238 (Online)
Application Date:03/12/2019
Name 2019 Seclusion Room Standards.pdf  Date:03/12/2019
2019 Cardinal ES Seclusion Room  3590 Hornaday Road 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 Ind Bldg Code-1008.1.9
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19238 The code requires egress doors to be readily openable from the egress side without the use of a key or special knowledge or effort. The request is to allow a lockset bolt to be used on the door of an elementary special education seclusion room. Proponent states staff member must remain present at the door to operate the lever. Once staff releases the lockset lever, the latch bolt retracts, and the door opens. Building is fully sprinklered as required. 
19239 (Online)
Application Date:03/12/2019
Name 2019 Seclusion Room Standards.pdf  Date:03/12/2019
2019 Eagle ES Seclusion Room  555 Sycamore St 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 Ind Bldg Code-1008.1.9
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19239 The code requires egress doors to be readily openable from the egress side without the use of a key or special knowledge or effort. The request is to allow a lockset bolt to be used on the door of an elementary special education seclusion room. Proponent states staff member must remain present at the door to operate the lever. Once staff releases the lockset lever, the latch bolt retracts, and the door opens. Building is fully sprinklered as required.  
19240 (Online)
Application Date:03/12/2019
Name 2019 BCSC Seclusion Room Standards.pdf  Date:03/12/2019
2019 Reagan ES Seclusion Room  4845 Bulldog Way 
Brownsburg 46112  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
HENDRICKS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 Ind Bldg Code-1008.1.9
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19240 The code requires egress doors to be readily openable from the egress side without the use of a key or special knowledge or effort. The request is to allow a lockset bolt to be used on the door of an elementary special education seclusion room. Proponent states staff member must remain present at the door to operate the lever. Once staff releases the lockset lever, the latch bolt retracts, and the door opens. Building is fully sprinklered as required.  
19241 (Online)
Application Date:03/12/2019
Name 4491 Annex First Floor.pdf  Date:03/12/2019
Name 4491 Annex Typical Upper Floor.pdf  Date:03/12/2019
Name 4491 Annex East Exterior Elevation.pdf  Date:03/12/2019
Name 4491 Annex West Exterior Elevation.pdf  Date:03/12/2019
Name 4491 Annex South Exterior Elevation.pdf  Date:03/12/2019
Annex on 10th - Phase II  1717 W. 10th St. 
Indianapolis 46222  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InMC 307.2.3

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC 1007.8

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InMC 501.3.1.3

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InMC, 918.6 Exc. 5.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 510.2 item 2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2009 ICC/ANSI A117.1, 1004.5.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC 1007.4

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 1209.2

19242 (Online)
Application Date:03/12/2019
Name Amy Beveraland ES Variance Exhibit - April 2019.pdf  Date:03/12/2019
Amy Beverland Elementary School   11650 Fox Road 
Indianapolis 46236  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
716.6, 2014 IBC
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19242 The code requires glazing in fire window assemblies to be fire protection rated. The request is to allow new glazing that will be installed in corridor walls separating the Media Center and the Maker Space to not be fire-rated. Fire-rated corridor construction is required based upon lack of sprinkler protection throughout the building. Media Center is an infill addition of an existing courtyard. Maker Space is a renovated area across the corridor from the Media Center. Sprinkler system will be provided throughout the area related to the variance, with a row of close-spaced sprinklers being provided on the room side of the windows, located a maximum of 12 inches horizontally from the windows at the ceiling level.  
19243 (Online)
Application Date:03/12/2019
Name Tipton Jail Overall 1st Floor Plan.pdf  Date:03/18/2019
Name Tipton Jail Overall 2nd Floor Plan.pdf  Date:03/18/2019
Name Mezzanine Section.pdf  Date:03/18/2019
Tipton County Jail  2300 W Indiana SR 28 
TIPTON 46072  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
TIPTON 
Code Name:2010 NFPA 13 Installation of Sprinkler Systems (675 IAC 28-1-5) [view code Details]
Specific Section:
Sec. 8.5.5.3.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19243 The code requires sprinklers to be installed under fixed obstruction over 4 ft. wide. The request is to allow sprinklers to be omitted below a 4¿-7¿ wide mezzanine. Proponent states the mezzanine is noncombustible with open grating and will only be used for walkway access to mezzanine cells. No storage will be on the mezzanine to obstruct the open grating.  
19244 (Online)
Application Date:03/12/2019
Name Guide Pointe Daycare_Plans.pdf  Date:03/18/2019
JC's Playhouse Childcare Facility at Guide Pointe Church  541 15th St 
Bedford 47421  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
LAWRENCE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3401.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19244 A Chapter 34 Evaluation will be used to convert a single family dwelling (Class 2 structure) into a building used as a 1-story (1,951 sq. ft.) with basement (516 sq. ft.) and mezzanine (539 sq. ft.) child care center. Chapter 34 is not permitted to be utilized for a conversion of a non-Class 1 structure building into an E occupancy. 
19245 (Online)
Application Date:03/12/2019
Name MedicinePlus_Plans.pdf  Date:03/20/2019
Name MedicinePlus20190320.pdf  Date:03/20/2019
Medicine Plus Pharmacy  2412 16th St 
BEDFORD 47421  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
LAWRENCE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 903.2.11.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19245 The code requires a sprinkler system to be provided throughout all stories, including basements, of all buildings where the floor area exceeds 1,500 sq. ft. and where there is no exterior wall openings for fire department access. The request is to allow the 3,000 sq. ft. basement to have neither exterior wall openings nor sprinkler system. Monitored fire alarm system will be provided in the building. Proponent states there is not enough room to provide exterior opening on the basement level due to the pharmacy drive-through on two sides of the building and parking on the other side.  
19246 (Online)
Application Date:03/12/2019
Name Queen City Candy Site Plan.pdf  Date:03/14/2019
Queen City Candy Building Additions  601 Rudolph Way 
Greendale 47025  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
DEARBORN 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 507.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19246 The code permits Group B, F, E, M, or S occupancies to be unlimited in area where the building is fully sprinklered and is surrounded by public ways or yards not less than 60 feet in width. The request is to allow two existing buildings on the same lot to be classified as unlimited area buildings without sprinklers being installed in the 12,800 sq. ft. building for up to 3 years from the date of the Commission hearing. Proponent states after the 3 years, they will either sprinkler the building or tear it down to add on to the existing unlimited area building.  
19247 (Online)
Application Date:03/12/2019
Name Whiting_Floor Plans.pdf  Date:03/19/2019
Whiting Phase I  1733-1739 119th Street 
Whiting 46394  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO Notified!
LBO Notified!
LAKE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 1007.8
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19247 The code requires a two-way communication system to be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge. The request is to allow the system to be omitted in the 5-story building. Cell phones will be used. Similar variances have been granted in the past.  
19248 (Online)
Application Date:03/12/2019
Name Kuehnert Dairy Farm Floor Plan.pdf  Date:03/14/2019
Kuehnert Dairy Farm  6532 W. Cook Rd. 
Fort Wayne 46818  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
ALLEN 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
12-4-11(b)
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19248 Clarification 
19249 (Online)
Application Date:03/12/2019
Name Bottleworks Site Image.pdf  Date:03/12/2019
Name Bottleworks West Elm Hotel Floor Plans.pdf  Date:03/12/2019
Name Bottleworks West Elm Hotel Sec 3412 Analysis - 8-9-18.pdf  Date:03/12/2019
Name Revised Table 3412-7 - Bottleworks West Elm Hotel.pdf  Date:03/12/2019
Bottleworks West Elm Hotel  831 Massachusetts Avenue 
Indianapolis 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
Table 3412.7, 2014
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19249 When using a Chapter 34 Evaluation to convert an existing occupancy to another occupancy, the code requires the final score to be zero or more in all categories in order to pass the Chapter 34 Evaluation. The request is to allow 5.1 additional points to be put to the Means of Egress and General Safety Columns in order to pass the evaluation. Proponent states the additional points are needed due to a discrepancy that was discovered when calculating the maximum travel distance. The maximum travel distance was originally calculated as 130 feet. The actual distance is 243 feet which is under the 250 feet allowed for new construction for fully sprinklered building. Corridors will be provided with smoke detection.  
19250 (Online)
Application Date:03/12/2019
Name 3630 Guion Rd - Map.pdf  Date:03/20/2019
Name Warehouse Layout_Sketch.pdf  Date:03/21/2019
Name Warehouse West End 1st Floor_Existing Plan.pdf  Date:03/21/2019
Name Warehouse West End 2nd Floor_Existing Plan.pdf  Date:03/21/2019
Name Warehouse East End_Existing Plan.pdf  Date:03/21/2019
Saturday Evening Post Storage Building  3630 Guion Rd 
Indianapolis 46222  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IFC Sec. 901.6
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19250 The code requires fire protection system to be maintained in accordance with the original installation. The request is to allow the existing sprinkler system to not be maintained. Sprinkler heads will be removed. Building was previously used to power the adjacent hospital. Boilers and other equipment are being removed. Building is being converted to a storage facility. Proponent states building is 2-stories with approximately 8,448 sq. ft. on the 1st floor and 2,905 sq. ft. on the 2nd floor. Building will not be regularly occupied. Current code would not require sprinklers in the storage building with less than 12,000 sq. ft. fire area. Are there enough exterior openings and correct size in each 50 linear feet, or fraction thereof? 
19251 (Online)
Application Date:03/12/2019
Name Sterling Boiler Culley Beta 2500 drawings.pdf  Date:03/14/2019
Name Sterling Boiler Culley TPS drawings.pdf  Date:03/14/2019
Vectren Corporation  3711 Darlington Rd. 
Newburgh   [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
WARRICK 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2004 ANSI A10.4, 11.3

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2004 ANSI A10.4, 11.3.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2004 ANSI A10.4,14.1.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2004 ANSI A10.4, 17.2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2004 ANSI A10.4, 10.1

19252 (Online)
Application Date:03/12/2019
Name Line Urban Flats_South Building_Enlarged Plan of Courtyard.pdf  Date:03/15/2019
Name Line Urban Flats_South Building_Partial Elevation_Courtyard Grill.pdf  Date:03/15/2019
Name Line Urban Flats_South Building_First Floor Overall.pdf  Date:03/15/2019
The Line Urban Flats - South Building  965 East 64th St 
INDIANAPOLIS 46220  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IFC Sec. 308.1.4
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19252 The code prohibits charcoal burners and other open-flame cooking devices from being operated on combustible balconies or within 10 feet of combustible construction. The request is to allow gas grill to be installed next to the combustible building in an open courtyard area, above non-combustible parking garage. The exterior wall behind the grill be brick veneer for the full 1st story of the combustible building. Patios surrounding the courtyard will be sprinklered as required.  
19253 (Online)
Application Date:03/12/2019
Name 4400 -First Floor Plan.pdf  Date:03/12/2019
Name 4400_Eleventh Floor Plan-Amenities.pdf  Date:03/12/2019
Name 4400_Twelveth Floor Plan-Typical.pdf  Date:03/12/2019
220 North Meridian  220 North Meridian St. 
Indianapolis 46204  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 3004.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 2902.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 713.14.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2009 ICC/ANSI A117.1, 1004.5.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2013 Ind Pool Code 20-2-5(a)

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2013 Ind Pool Code 20-2-27

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC 1007.8

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 1209.2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ANSI A117.1-2009,1004.12.2.5
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:Correct code section 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2013 Ind Pool Code 20-2-13(d)

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 1018.4

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2013 Ind Pool Code 20-2-26

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, 1004.1.2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC, Table 1014.3

19254 (Online)
Application Date:03/12/2019
Name Summit MS Variance Exhibit.pdf  Date:03/12/2019
Name Summit MS - Classroom sq footages.docx  Date:03/14/2019
Summit Middle School Locker Installation  4509 Homestead Road 
Fort Wayne 46804  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
ALLEN 
Code Name:12-4-12 Existing Buildings; Additions or Alterations [view code Details]
Specific Section:
Rule 4, Section 12(d)
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19254 The code prohibits addition or alteration from reducing exit capacities to a level less than that required of the rules of the Commission for new construction. The request is to allow lockers to be added within corridors due to an expected increase in school enrollment. Proponent states the addition of lockers do not decrease the required corridor width. Currently corridor width is 10 feet. Rows of lockers to be placed alongside corridors will be 12 inches in depth, reducing corridors to 9 feet in width. Per the proponent, the minimum corridor width for schools is 6 feet. Variance was filed per State Code Enforcement request.  
19255 (Online)
Application Date:03/12/2019
Name Trinity_First Floor Plan.pdf  Date:03/19/2019
Trinity Episcopal Church  611 W Berry St 
Fort Wayne 46802  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 1018.1
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19255 The code requires corridor construction in Group A occupancy to be one hour fire rated when the occupant load it serves is 30 or greater and the building is not fully sprinklered. The request is to allow new corridor walls to be non-rated. Proponent states minor renovation will be done to the existing church. Per the proponent, the existing corridor walls are not rated.  
19256 (Online)
Application Date:03/12/2019
Name Lewis_A001-Life Safety Plans.pdf  Date:03/19/2019
Name Lewis Event Barn_Chapter 34.pdf  Date:03/19/2019
Name Lewis Event Barn_Structural Report.pdf  Date:03/19/2019
Lewis Event Barn  7234 W 200 S 
Jamestown 46147  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
BOONE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3401.3, 2902.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19256 (a) Restroom fixture count will not comply with code. The request is to allow portable restrooms to be used temporarily to comply with the fixture count requirements. Permanent restroom facilities will be added within 1 year of opening. Portable restrooms will comply with accessibility. Drinking water will be available for occupants during events. Similar variances have been approved in the past.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3401.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) A Chapter 34 analysis will be used to convert a 1-story (4,387 sq. ft.) plus mezzanine/lofts (1,105 sq. ft.) barn, Type V-B construction, into a building used for event space. Chapter 34 is not permitted to be utilized for a conversion of a non-Class 1 structure building to an A occupancy. Proponent states lofts will be used for DJ space and dressing room, not assembly. Three exits will be provided with capacity of 850 persons. Per the proponent, calculated occupant load is 254. Decorative combustible materials will be fire retardant treated. Decorative lighting will be commercial grade. Shunt trip will be provided. Structural evaluation included.  
19257 (Online)
Application Date:03/12/2019
Name Hurco Photos and Fire Code Excerpts.pdf  Date:03/12/2019
Name Hurco Fire Protection Plans - 1990.pdf  Date:03/12/2019
Hurco Small Hose Valves  1 West Technology Way  
Indianapolis 46268  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:12-4-9 Maintenance of Existing Buildings and Structures [view code Details]
Specific Section:
Rule 4, Section 9(d)

19258 (Online)
Application Date:03/12/2019
Name Barn 38_A100-Life Safety Plans.pdf  Date:03/20/2019
Name Barn 38_Chapter 34.pdf  Date:03/20/2019
Name Barn 38_Structural Report.pdf  Date:03/20/2019
Barn 38  1890 W St Rd 38 
New Castle 47362  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
HENRY 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3401.3, 2902.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19257 (a) Restroom fixture count will not comply with code. The request is to allow portable restrooms to be used temporarily to comply with the fixture count requirements. Permanent restroom facilities will be added within 1 year of opening. Portable restrooms will comply with accessibility. Drinking water will be available for occupants during events. Similar variances have been approved in the past.  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3412.7
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:WITHDRAWN BY PROPONENT 03/21/19. 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 3401.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:(b) A Chapter 34 analysis will be used to convert a 2-story 5,956 sq. ft. on first floor and 2,670 sq. ft. on the second floor barn, Type V-B construction, into a building used for event space. Chapter 34 is not permitted to be utilized for a conversion of a non-Class 1 structure building to an A occupancy. Proponent states second story loft has an exterior stairway giving direct exit from the 2nd floor to open porch. Travel distance to nearest exit will be less than ½ of what¿s required. Decorative combustible materials will be fire retardant treated. Decorative lighting will be commercial grade. Shunt trip will be provided. Structural evaluation included.  
19259 (Online)
Application Date:03/12/2019
Name Childrens Autism Center 10820 Coldwater Floor Plan 1.pdf  Date:03/12/2019
Name Childrens Autism Center 10820 Coldwater Floor Plan 1.pdf  Date:03/12/2019
Children's Autism Center  10820 Coldwater Road 
Fort Wayne 46845  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
Rule 4, Section 11(b), GAR
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19259 The code prohibits a building from changing its character or use causing it to be classified within a different occupancy group, unless the building is made to comply with new construction. A 3,700 sq. ft. tenant space that was previously used as a "B" occupancy is being used as an "I-4" occupancy, autism children, without complying with the rules for new construction for the "I-4" occupancy. The request is to allow Variance 18-04-16, due to expire April 30, 2019, be extended for an additional 12 months as an "I-4" occupancy. Proponent states the tenant space was cited due to the change of use not being in compliance with "I-4" requirements. Ages range from 2 - mid 20's with a maximum of 20 clients being in the building at one time.  
19260 (Online)
Application Date:03/12/2019
Name PROGressive mat Factory First Floor Plan.pdf  Date:03/12/2019
Name Progressive mat 13 Site Plan.pdf  Date:03/12/2019
Name PROG 013 Office First Floor Plan.pdf  Date:03/12/2019
Progressive Materials  Hausfeldt Lane 
New Albany 47150  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
FLOYD 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, Table 503
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19260 The code prohibits buildings or structures from exceeding the height, number of stories, and allowable area based on the construction type. The request is to allow a 71,000 sq. ft. new facility that will be storing Class I-B, II, III-A, and III-B materials in raw and finished materials, classified as H-2/H-3 occupancy, to be over allowable area for Type II-B construction. Building will be protected with foam sprinkler system. What is the allowable area? 
19261 (Online)
Application Date:03/12/2019
Name Childrens Autism Center 10816-10818 Coldwater Floor Plan.pdf  Date:03/12/2019
Childrens Autism Center  10816 and 10818 Coldwater Road 
Fort Wayne 46845  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
Rule 4, Section 11(b), GAR
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19261 The code prohibits a building from changing its character or use causing it to be classified within a different occupancy group, unless the building is made to comply with new construction. A 1,800 sq. ft. tenant space that was previously used as a "B" occupancy is being used as an "I-4" occupancy, autism children, without complying with the rules for new construction for the "I-4" occupancy. The request is to allow Variance 18-04-17, due to expire April 30, 2019, be extended for an additional 12 months as an "I-4" occupancy. Proponent states the tenant space was cited due to the change of use not being in compliance with "I-4" requirements.  
19262 (Online)
Application Date:03/12/2019
Name Barr Reeve_Floor Plan.pdf  Date:03/19/2019
Barr-Reeve Community Schools Gymnasium Addition  627 N 3rd Street 
Montgomery 47558  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
DAVIESS 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IFC Sec. 3311.2
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19262 (a) Required means of egress is to be maintained during construction and demolition, remodeling or alterations and additions to any building. The request is to allow a new addition to the existing school to impact the means of egress and require temporary means of egress during construction. Exits will be closed at the new addition. Exit lighting and signs will be modified to the new egress system. Fire drills will be conducted to familiarize students and faculty of the revised egress routes. Construction will be from June 2019 to April 2020.  
Code Name:12-4-12 Existing Buildings; Additions or Alterations [view code Details]
Specific Section:
Rule 4, Section 12(f)

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 706.2

19263 (Online)
Application Date:03/12/2019
Name VARIANCE Main St Mech Enlarged Lobby.pdf  Date:03/12/2019
Name VARIANCE Berner-Air-Curtain-Architectural-Low-Profile-8-FLYER-2017.pdf  Date:03/12/2019
Name VARIANCE Main St - Jeremiah full building.pdf  Date:03/12/2019
310 On Main  310 N Main St 
AUBURN 46706  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
DEKALB 
Code Name:2010 Indiana Energy Conservation Code (675 IAC 19-4) [view code Details]
Specific Section:
5.4.3.4
Staff Recommendation:B (explanation key at the top of the table)

Staff Comments:19263 The code requires building to have a vestibule if the space served by the door is 3,000 sq. ft. or more. The request is to allow an air curtain to be installed at the entrance of a 4,923 sq. ft. restaurant in lieu of the vestibule. Similar variances have been granted in the past.  
19264 (Online)
Application Date:03/12/2019
Name Cargo Streetwear Shipping Container_Code Compliance Narrative.pdf  Date:03/15/2019
Name Cargo Streetwear_Plans.pdf  Date:03/20/2019
Name Shipping Container Structural Letter.pdf  Date:03/20/2019
Cargo Streetwear Boutique  2328 Shelby St 
Indianapolis 46203  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 2902.1
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19264 (a)  
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
GAR 12-4-7

19265 (Online)
Application Date:03/12/2019
Name Whitestown Fire Station_Plans.pdf  Date:03/19/2019
Whitestown Fire Station  S Indianapolis Rd 
Whitestown 46075  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
BOONE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC Sec. 1103.1
Staff Recommendation:A (explanation key at the top of the table)

Staff Comments:19265 The code requires buildings, structures, facilities, elements and spaces, to be accessible to person with physical disabilities. The request is to allow the 3-story fire station to have its area used by firefighting personnel to not be accessible. Accessible rest rooms will be provided for use by the public and staff personnel on the 1st floor.  
19266 (Online)
Application Date:03/14/2019
Name Heavilin ES CD Arch Drawings.pdf  Date:03/14/2019
valparaiso New Elementary School  2300 Heavilin Road  
Valparaiso 46383  [ view application in html]
[ view app in pdf for IE ]
Designer Affirmation Pending!
LFO Notified!
LBO acknowledgement received!
PORTER 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC 903.2.3
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19266 ******* 
19267 (Online)
Application Date:03/15/2019
Name New Office Finals.pdf  Date:03/15/2019
New Office Building Hammond  2901 Carlson 
Hammond 46323  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
LAKE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1,2.18.5.

19268 (Online)
Application Date:03/15/2019
Name Gates ft1 cert.pdf  Date:03/15/2019
Name Shackle installation.pdf  Date:03/15/2019
Name Belt Design.pdf  Date:03/15/2019
Name Shackle Drawing.pdf  Date:03/15/2019
Name Shackle Counterside Installation.pdf  Date:03/15/2019
Name Belt Spec.pdf  Date:03/15/2019
Name Belt TOC 1-28-15.docx  Date:03/15/2019
Name Evolution 200 Inspector's Guide 44103.pdf  Date:03/15/2019
Name EVO Belts.pdf  Date:03/15/2019
Name Belt LETTER 1.doc  Date:03/15/2019
The Post House  123 NW 3RD St. 
Evansville 47708  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
VANDERBURGH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.14.1.7.1,2.20.2.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.3,2.20.9,2.25.3,2.20.1

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 2.20.2.2

19269 (Online)
Application Date:03/18/2019
Name Bell Tower West Floor Plan.pdf  Date:03/18/2019
Bell Tower West  171 93 rd Ave 
Merrillville   [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO acknowledgement received!
LBO Notified!
LAKE 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 1018.4

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 IBC, 407.2

19270 (Online)
Application Date:03/18/2019
Name Mad Paddle Floor Plan.pdf  Date:03/18/2019
Name Hanover Event Drawing May 2019-sml.pdf  Date:03/18/2019
Hanover College Alumni Award Ceremony After Party   301 West Street 
Madison 47250  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
MADISON 
Code Name:12-4-11 Change of Occupancy or Use of Existing Buildings [view code Details]
Specific Section:
Rule 4, Section 11(b), GAR
Staff Recommendation:C (explanation key at the top of the table)

Staff Comments:19270 ***** 
19271 (Online)
Application Date:03/19/2019
Name 20181128_131318.jpg  Date:03/19/2019
Name 20181128_131419.jpg  Date:03/19/2019
Name 20181128_131428.jpg  Date:03/19/2019
Name 20181128_131518.jpg  Date:03/19/2019
Name 20181128_131826.jpg  Date:03/19/2019
Name 20181128_131838.jpg  Date:03/19/2019
Name 20181128_131921.jpg  Date:03/19/2019
Name SHS 88 A201.pdf  Date:03/19/2019
Southport High School  971 E. Banta 
Indianapolis 46227  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
LFO Notified!
LBO Notified!
MARION 
Code Name: [view code Details]
Specific Section:
903.3.1.1.1

19280 (Online)
Application Date:03/20/2019
Midtown Place  120 W Washington Blvd. 
Fort Wayne 46802  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
ALLEN 
Code Name: [view code Details]
Specific Section:
ANSI ASME A 17.1-2007

19281 (Online)
Application Date:03/20/2019
Holiday Inn Express  1548 Shook Dr. 
Auburn 46706  [ view application in html]
[ view app in pdf for IE ]
Ready for IDHS processing!
LFO acknowledgement received!
LBO acknowledgement received!
DEKALB 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1 and 2 2

19282 (Online)
Application Date:03/20/2019
Holiday Inn Express  1548 Shook Dr. 
auburn 46706  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
DEKALB 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1 and 2 2

19283 (Online)
Application Date:03/20/2019
Name H-MRL Code Deviations.pdf  Date:03/20/2019
Cummins Corporate Office Building Renovation  500 Jackson St 
COLUMBUS 47201  [ view application in html]
[ view app in pdf for IE ]
LFO acknowledgement received!
LBO Notified!
BARTHOLOMEW 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
ASME A17.1 2007 3.26.8

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
3.19.4.1,3.19.4.4,3.19.4.5

19284 (Online)
Application Date:03/20/2019
Name 2019-0320 FDC State Variance Request (G BLOC).pdf  Date:03/20/2019
Name 2019-0320 IFD Variance request (G BLOC) CAS signed.pdf  Date:03/20/2019
Name 2019-0320 FDC State Variance Request (G BLOC).pdf  Date:03/20/2019
G BLOC  841 E. 64th Street 
Indianapolis 46219  [ view application in html]
[ view app in pdf for IE ]
Owner Affirmation Pending!
Designer Affirmation Pending!
LFO acknowledgement received!
LBO acknowledgement received!
MARION 
Code Name:2010 NFPA 13 Installation of Sprinkler Systems (675 IAC 28-1-5) [view code Details]
Specific Section:
912.2.1

19285 (Online)
Application Date:03/21/2019
Name idhs_fire_code_insp_report (003).pdf  Date:03/22/2019
Name NDI VARIANCE APP.pdf  Date:03/22/2019
IFSSA Neurodiagnostic Institute  5435 East 16th Street 
INDIANAPOLIS 00000  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
MARION 
Code Name:2008 Indiana Fire Code (675 IAC 22-2.4) [view code Details]
Specific Section:
2010 EDITION NFPA 72 18.3.3.2*

19286 (Online)
Application Date:03/22/2019
Mill at Ironworks Plaza  235 Ironworkd Dr. 
Mishawaka 46544  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO acknowledgement received!
ST JOSEPH 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1 and 2 2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1 and 2 2

Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2.20.1,2.20.4,2.20.9 1 and 2 2

19287 (Online)
Application Date:03/25/2019
Name Schneck Pharmacy fire dampers.pdf  Date:03/25/2019
Schneck Pharmacy Expansion  411 W Tipton St 
SEYMOUR 47274  [ view application in html]
[ view app in pdf for IE ]
LFO Notified!
LBO Notified!
JACKSON 
Code Name: Other Code (Not in the list provided) [view code Details]
Specific Section:
2014 InBC 717.6.1