DHS

Indiana Department of Homeland Security / Fire and Building Safety Division

2020-21 version

 

Update Inspection

[Open Report in Chrome Browser]
[back to inspection list]
[view and Print Report (No Notes)]
[view and Print Report with Notes]
__________________________
Record Created Date: 01/10/2013
* facility ID:
* facility name:
* facility street number:
* facility street prefix:
* facility street name:
* facility street suffix:
facility address2:
* facility city:
* facility county:
facility state: IN
* facility zip:
* facility contact:
* facility telephone:
* facility Email:
Foundation/Footer status:
Concrete Slab status:
Framing Status:
Plumbing status:
Mechanical status:
Electrical status:
Energy status:
Sprinkler status:
alarm status:
sensitivity current :
Interior status:
Pool status:
Egress status:
Suppression status:
temporary indoor stage:
temporary outdoor stage:
outdoor stage equipment :
canopy:
tent :
ust installation:
ust removal:
project Type(select ll that apply): New: Addition: Remodel: Occ.Change: Existing:
inspection Category:
inspection type:
inspection status:
inspection Date: (mm/dd/yyyy)Pick a date
violation to be corrected by Date: (mm/dd/yyyy)Pick a date
* inspector:
notes:
Facility Match?: (Type in Facility Matched, when you match a complaint inspection with facility.)
[view & print annual permit] [Email permit]
print order code description remarks violation to be corrected by date violation complied date

Sec. 605.6 2008 Edition IFC 675 IAC 22-2.4 
Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 
Replace the cover plates by the hot water heater and by the conner table in the main bar area. 
02/11/2013 
 

675 IAC 12-9-3 
(a) An applicant for an annual amusement and entertainment permit shall submit an application, with the applicable fee as set in IC 22-12-6-7, to the state fire marshal on forms provided by the division. An application may be submitted as early as September 1 of the year preceding the calendar year for which a permit will cover. Each application shall provide the information required by IC 22-14-3-3 and the following: (1) A listing of each use, giving the: (A) days and hours of operation of regularly scheduled events; and (B) dates and inclusive times of special events planned to be conducted; in the calendar year for which a permit is to cover. (2) An attached floor plan or site plan showing the following: (A) The planned arrangement of other than fixed seating. (B) The location of the following: (i) Aisles. (ii) Exit ways. (iii) Barriers. (iv) Steps. (v) Other crowd movement or control facilities, equipment, signs, or personnel. (3) The maximum occupancy intended for both seated and standing attendees. (4) The name, address, and telephone number of the person to be contacted to arrange for inspections by the state fire marshal. 
This facility has events that would require an entertainment permit and their permit expired on 1-4-2013 
02/11/2013 
 

Sec. 1006.3 2008 Edition IFC 675 IAC 22-2.4  
The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.  
Repair the emergency light over the front door, one side failed to work. 